Procedure
- Before you begin
- - All centrifugation steps should be carried out at 16,000 x g (~13,000 RPM)
- - Add 4 volumes of ethanol (>95%) to one volume of Plasmid Wash Buffer 2
- CRITICALOnly do this if you are using the Monarch miniprep kit for the first time
- - If precipitate has formed in Lysis Buffer (B2), incubate at 30-37oC, inverting periodically to dissolve
- - Store Plasmid Neutralization Buffer (B3) at 4oC after opening (store on ice or in fridge)
- Protocol
- Pellet 1-5ml bacterial culture by centrifugation for 30 seconds. Discard supernatent
- - Recommend 1.5ml in a microcentrifuge tube
- - If cells grown in 6mL liquid cultures overnight, do 1.5mL twice (discardign supernatent after first centrifuge and adding another 1.5mL into the same tube) and begin pre-warming nuclease free water (nf-H2O) at 37oC
- Resuspend pellet in 200ul Plasmid Resuspension Buffer (B1)
- - Vortex or pipet to ensure cells re completely resuspended.
- - There should be no visible clumps
- Add 200ul Plasmid Lysis Buffer (B2), gently invert tube 5-6 times and incubate at room temperature for 1 minute
- - Colour should change to dark pink and solution will become transparent and viscous
- CRITICALDO NOT VORTEX
- Add 400ul of Plasmid Neutralization Buffer (B3), gently invert tube until neutralized and incubate at room temperature for 2 minutes
- - Sample is neutralized when colour is uniformly yellow and precipitate forms
- CRITICALDO NOT VORTEX
- Centrifuge lysate for 2-5 minutes
- Carefully transfer supernatent to spin column and centrifuge for 1 minute and discard the flow-through
- Re-insert column in the collection tube and add 200ul of Plasmid Wash Buffer 1 then centrifuge for 1 minute
- - Discarding flow-through is option
- Add 400ul of Plasmid Wash Buffer 2 and centrifuge for 1 minute
- - Recommend do a dry spin for 1 minute after this step but not absolutely necessary
- Transfer column to a clean 1.5ml microfuge tube
- - Use care to ensure that the tip of the column does not come into contact with the flow-through
- - If any doubt, do a dry-spin
- Add 30ul or more (recommend 50uL) of DNA Elution Buffer to center of matrix then wait for 1 minute and spin for 1 minute to elute DNA
- - Nuclease-free water (pH 7-8.5) can be used instead of DNA Elution Buffer
- - For larger size DNA (10kb or more), heating elution buffer to 50oC prior to use