Figure 3 and 4 show that fluorescence intensity is correlated to promoter strength of each device. The fluorescence emission level of device 1 is more important than device 2. Device 2 presents a more important fluorescence emission level than device 3. The positive control show a large range of fluorescence intensity, containing two peaks. This probably means that there might be two subpopulations, expressing GFP at different levels. In other terms, two colonies were probably picked and inoculated instead of one in the liquid medium. Those two subpopulations probably don't have the same number of plasmids inside each cell, which leads to different fluorescence emission intensity. However, positive control fluorescence level is around the same as device 2. As expected, negative control does not show any significant fluorescence emission.
Figure 3 and 4 show that fluorescence intensity is correlated to promoter strength of each device. The fluorescence emission level of device 1 is more important than device 2. Device 2 presents a more important fluorescence emission level than device 3. The positive control show a large range of fluorescence intensity, containing two peaks. This probably means that there might be two subpopulations, expressing GFP at different levels. In other terms, two colonies were probably picked and inoculated instead of one in the liquid medium. Those two subpopulations probably don't have the same number of plasmids inside each cell, which leads to different fluorescence emission intensity. However, positive control fluorescence level is around the same as device 2. As expected, negative control does not show any significant fluorescence emission.
−
Table1
+
{| class="wikitable"
+
|-
+
!Constructions
+
!Sample
+
!# of events
+
!FL1 median
+
|-
+
|Negative Control
+
|#1
+
|1 000 980
+
| 13
+
|-
+
|
+
|#2
+
|1 005 646
+
|18
+
|-
+
| Positive control
+
|# 1
+
|1 002 586
+
|2 217
+
|-
+
|
+
| #2
+
|1 004 747
+
| 3 830
+
|-
+
| Test Device 1
+
|# 1
+
|1 028 072
+
|23 572
+
|-
+
|
+
|#2
+
|1 021 552
+
|23 990
+
|-
+
| Test Device 2
+
|# 1
+
|1 003 942
+
|4 571
+
|-
+
|
+
|#2
+
|1 006 803
+
|4 458
+
|-
+
| Test Device 3
+
|# 1
+
|1 011 107
+
| 66
+
|-
+
|
+
|# 2
+
| 1 012 481
+
|68
+
|}
+
+
Table 1: detailed cytometry data
+
This figure shows detailed measurment data for each sample.
+
Detailed data (Table I) show that fluorescence intensity results does not vary between two samples of the same construction, except for the positive control. This observation has to be linked with the fact that the positive control cells population might not be homogeneous.
Detailed data (Table I) show that fluorescence intensity results does not vary between two samples of the same construction, except for the positive control. This observation has to be linked with the fact that the positive control cells population might not be homogeneous.