Difference between revisions of "Team:Slovenia/Model"

Line 85: Line 85:
 
<h2><span id = "intro" class = "section"> &nbsp; </span>Ultrasound propagation modeling</h2>
 
<h2><span id = "intro" class = "section"> &nbsp; </span>Ultrasound propagation modeling</h2>
 
<p>Ultrasound are sound waves with frequencies higher than upper audible limit of human hearing, i.e. higher than 20 kHz.  
 
<p>Ultrasound are sound waves with frequencies higher than upper audible limit of human hearing, i.e. higher than 20 kHz.  
In the frequency range between 0.8 and 5 Mhz, the sound wave length is between 2 and 0.3 mm. Ultrasound is mainly used for diagnostic purposes as unlike light it can easily penetrate the tissue and is at those intensities completely harmless and is therefore used for diagnostics in pregnancies. Short wavelengths, enable us to create small regions of high intensity focused ultrasound at the focal point,  
+
In the frequency range between 0.8 and 5 Mhz, the sound wave length is between 2 and 0.3 mm. Ultrasound is mainly used for diagnostic  
which can be used for therapeutic purposes <x-ref>escoffre2016therapeutic</x-ref> such as for the tissue ablation. High intensity focused ultrasound has been already used in thermal ablation therapies <x-ref>escoffre2016therapeutic</x-ref>. In vital organs like brain it is particularly important to focus high intensity ultrasound beam at the small targeted structure in order to avoid unwanted tissue damage.  
+
purposes. Unlike light ultrasound can easily penetrate the tissue and is at those intensities completely harmless. It is therefore used also in  
 +
prenatal diagnostics where non-invasivness is of vital importance. Short wavelengths additionally enable us to create small regions of high intensity focused ultrasound waves at the focal point,  
 +
which can be used for therapeutic purposes <x-ref>escoffre2016therapeutic</x-ref> for example for the tissue ablation. High intensity focused  
 +
ultrasound has been already used in thermal ablation therapies <x-ref>escoffre2016therapeutic</x-ref>. In vital organs like brain it is particularly  
 +
important to focus high intensity ultrasound beams at the small targeted structure in order to avoid unwanted tissue damage.  
 
</p>
 
</p>
 
<p>
 
<p>
Based on our improvement of the of ultrasound responsiveness of the cells it would be feasible to introduce the genetic device into the target tissue and then selectively activate only cells by using focused ultrasound, where the sound pressure is sufficiently high. This would enable for example stimulation of neurons in the selected brain section to achieve noninvasive deep brain stimulation or stimulate cells that produce hormones.
+
Based on our improvement of the ultrasound responsiveness of the cells it would be feasible to introduce a genetic device into the target tissue and then selectively activate only specific cells by using focused ultrasound, causing a sufficient intensity of the acoustic pressure. This would for example enable the stimulation of neurons in the selected brain section to achieve non-invasive deep brain stimulation or to stimulate cells to produce different hormones.
 
</p>
 
</p>
 
<p>
 
<p>
For this purpose we designed a model of the ultrasound propagation to investigate the setup of the ultrasound device that we constructed, potentially using multiple ultrasound probes.
+
For this purpose we designed a model of the ultrasound propagation. The model can guide us in the process of the ultrasound device calibration with the potential to use multiple ultrasound probes.
 
</p>
 
</p>
 
</div>
 
</div>
Line 134: Line 138:
 
<br />
 
<br />
 
<p>
 
<p>
Sound is a vibration that propagates as a mechanical wave of pressure and displacement through the medium. The speed of its propagation depends on the properties of the medium.
+
Sound is a vibration that propagates as a mechanical wave of pressure and displacement through the medium. The speed of its propagation also depends on the properties of the medium.
This means that speed of sound varies greatly between different types of tissue <x-ref>azhari2010basics</x-ref>. The speeds of sound in different tissue and in the air are listed in (<ref>2</ref>).
+
This means that the speed of sound varies greatly between different types of tissues <x-ref>azhari2010basics</x-ref>. The speed of sound propagation in different tissue in comparison to its propagation through air is represented in (<ref>2</ref>).
 
</p>
 
</p>
 
 
Line 175: Line 179:
 
<br />
 
<br />
 
<p>
 
<p>
For a realistic simulation of the brain an MR image (<ref>3</ref>) was used from <x-ref>mollerpocket</x-ref> and the tissue segmentation was made by medical experts, our team members, students of medicine (Kosta, Samo and Nina) (<ref>4</ref>).
+
In order to achieve a realistic simulation of the sound propagation through brain an MR image represented in <ref>3</ref> was used <x-ref>mollerpocket</x-ref>. Furthermore, we performed the tissue segmentation with the aid of medical experts, i.e. our team members, students of medicine (Kosta, Samo and Nina) (<ref>4</ref>).
 
</p>
 
</p>
 
<div style = "float:left;">
 
<div style = "float:left;">
Line 186: Line 190:
 
<figure data-ref="4">
 
<figure data-ref="4">
 
<img onclick = "resize(this);" class="ui medium image" src="//2016.igem.org/wiki/images/f/f8/T--Slovenia--Segm_head.jpg"> </img>
 
<img onclick = "resize(this);" class="ui medium image" src="//2016.igem.org/wiki/images/f/f8/T--Slovenia--Segm_head.jpg"> </img>
<figcaption>The segmentation of head section, where the green colour represents skin, blue colour represents bone, cyan colour represents the cerebrospinal fluid, dark grey colour represents grey brain matter and light grey colour represents white brain matter. While the speed of sound does not vary much between dark and white grey matter it is sufficient to model only brain matter in general.</figcaption>
+
<figcaption>The segmentation of head section, where the green color represents skin, blue color represents bone, cyan color represents the cerebrospinal fluid, dark grey color represents grey brain matter and light grey color represents white brain matter. While the speed of sound does not vary much between dark and white grey matter it is sufficient to model only brain matter in general.</figcaption>
 
</figure>
 
</figure>
 
</div>
 
</div>
Line 199: Line 203:
 
</div>
 
</div>
 
<p>
 
<p>
The probes in our model are capable of emitting sound waves at frequencies ranging from 0.5 Mhz to 5 Mhz at acoustic pressure from 10 kPa to 100 kPa. The focused probes that we used have focal length of 7 cm. Besides focused probes we also modeled unfocused probes. Both types have an aperture of 4.4 cm.
+
The probes in our model are capable of emitting sound waves at frequencies ranging from 0.5 Mhz to 5 Mhz at acoustic pressure from 10 kPa to 100 kPa. The focused probes that we used have focal length of 7 cm. Besides focused probes we also modeled unfocused probes. Both types of probes have an aperture of 4.4 cm.
 
In general propagation of sound from the focused probe can be approximated with an analytic function of a Gaussian beam (<ref>6</ref>), but this representation fails when we want to model wave interferences from multiple probes. For such cases wave equation model needs to be established.  
 
In general propagation of sound from the focused probe can be approximated with an analytic function of a Gaussian beam (<ref>6</ref>), but this representation fails when we want to model wave interferences from multiple probes. For such cases wave equation model needs to be established.  
 
</p>
 
</p>
Line 215: Line 219:
 
\end{equation}
 
\end{equation}
  
While wave equation cannot be solved analytically, one can approximate it with finite difference method. Let's presume we want to approximate the solution on a square area. First we discretize the area to obtain the grid of evenly distributed points $(x_{i}, y_{j})$, $i,j = 1,...,n$. The Laplace operator can now be approximated:
+
While wave equation cannot be solved analytically, one can approximate it with finite difference method. Let's presume we want to approximate the solution on a squared area. First we need to discretize the area to obtain the grid of evenly distributed points $(x_{i}, y_{j})$, $i,j = 1,...,n$. The Laplacian operator can now be approximated as:
  
 
\begin{equation}
 
\begin{equation}
Line 227: Line 231:
 
\end{equation}   
 
\end{equation}   
  
These equation can be simplified to first order differential equations with the introduction of new variable that represents the speed: $(v_{i, j} = \dot{p}_{i, j})$. The new system now has the following form:
+
These equation can be simplified to the first order differential equations with the introduction of a new variable that represents the speed: $(v_{i, j} = \dot{p}_{i, j})$. The new system now has the following form:
 
\begin{equation}
 
\begin{equation}
 
\begin{aligned}
 
\begin{aligned}
Line 235: Line 239:
 
\end{equation}
 
\end{equation}
  
The dispersion of waves is already included in wave equation, but absorption of sound waves in tissue is not included. However, absorption can be approximated with the introduction of the attenuation coefficient $k$. We fitted attenuation coefficient to experimental data <x-ref>sprawls1989ultrasound</x-ref>, $k = 16000$ for soft tissue and $k = 160000$ for bone tissue.  
+
The dispersion of the waves is already included in the wave equation. However, the absorption of sound waves in tissue is not included. The absorption can be approximated with the introduction of the attenuation coefficient $k$. We fitted attenuation coefficient to experimental data <x-ref>sprawls1989ultrasound</x-ref> to obtain, $k = 16000$ for soft tissue and $k = 160000$ for bone tissue.  
The final equation now has a form:
+
The final equation now has the form:
 
\begin{equation}
 
\begin{equation}
 
\dot{v}_{i, j} = \frac{c^2}{h^2}(p_{i + 1, j} + p_{i-1, j} + p_{i, j + 1} + p_{i, j - 1} - 4p_{i,j}) - k*v_{i,j}
 
\dot{v}_{i, j} = \frac{c^2}{h^2}(p_{i + 1, j} + p_{i-1, j} + p_{i, j + 1} + p_{i, j - 1} - 4p_{i,j}) - k*v_{i,j}
Line 248: Line 252:
 
</div>
 
</div>
 
<p>
 
<p>
Finally we can solve given system with iterative numeric methods like Euler's method or Runge-Kutta method. The most widely known method of the Runge-Kutta family is RK4, which we also used in our model.  
+
Finally we can solve the given system with iterative numeric methods such as Euler's method or Runge-Kutta method. The most widely known method of the Runge-Kutta family is RK4, which was also used in our model.  
 
While RK4 introduces some computational overhead it also significantly increases the numerical stability of the system in comparison to the Euler's method.  
 
While RK4 introduces some computational overhead it also significantly increases the numerical stability of the system in comparison to the Euler's method.  
 
The most basic steps used for the calculation of ultrasound propagation are displayed in (<ref>5</ref>).
 
The most basic steps used for the calculation of ultrasound propagation are displayed in (<ref>5</ref>).
Line 261: Line 265:
 
<h2><span id = "results" class = "section"> &nbsp; </span> Results</h2>
 
<h2><span id = "results" class = "section"> &nbsp; </span> Results</h2>
 
<p>
 
<p>
Simulation computed with our model (<ref>7</ref>) clearly shows that it is possible to target small regions of brain tissue. We can also observe the one dimensional cut of acoustic pressure, where focusing is even more evident (<ref>8</ref>). The probe on the right is slightly displaced due to asymmetry in tissue. This clearly shows that models need to be applied to calculate the optimal position of ultrasound probes.  
+
Simulations computed with our model (<ref>7</ref>) clearly show that it is possible to target small regions of brain tissue. We can also observe the one dimensional cut of acoustic pressure, where focusing is even more evident (<ref>8</ref>). The probe on the right is slightly displaced due to the asymmetry of the tissue. This clearly shows that models need to be applied to calculate the optimal position of ultrasound probes.  
 
Such software will include automatic tissue segmentation, modeling of propagation of ultrasound waves and will assist experts in probe positioning. Our model is a step in that direction, since it can be used as a tool for positioning the probes. In the model that we generated focused and unfocused probes can be added or removed and positioned. Additionally probe's acoustic pressure and frequency can be set.   
 
Such software will include automatic tissue segmentation, modeling of propagation of ultrasound waves and will assist experts in probe positioning. Our model is a step in that direction, since it can be used as a tool for positioning the probes. In the model that we generated focused and unfocused probes can be added or removed and positioned. Additionally probe's acoustic pressure and frequency can be set.   
 
</p>
 
</p>
Line 267: Line 271:
 
<figure data-ref="7">
 
<figure data-ref="7">
 
<img class="playGif ui big centered image" src="//2016.igem.org/wiki/images/4/4a/T--Slovenia--USModelThumbnail.png" data-alt="//2016.igem.org/wiki/images/c/c0/T--Slovenia--Usmodel.gif">
 
<img class="playGif ui big centered image" src="//2016.igem.org/wiki/images/4/4a/T--Slovenia--USModelThumbnail.png" data-alt="//2016.igem.org/wiki/images/c/c0/T--Slovenia--Usmodel.gif">
<figcaption>The propagation of ultrasound waves through brain tissue as computed with our model. One can observe the small focused area in the middle of the brain (Fornix). We can also detect green specks in the bone region, which is due to the reflection of sound waves. Since the speed of sound in the bone is much higher, the wavelength also increases in that area.
+
<figcaption>The propagation of ultrasound waves through brain tissue as computed with our model. One can observe the small focused area in the middle of the brain (Fornix). We can also detect green specks in the bone region, which are caused by the reflection of the sound waves. Since the speed of sound in the bone is much higher than the speed in soft tissue, the acoustic wavelengths in the bone are increased.
 
</figcaption>
 
</figcaption>
 
</figure>
 
</figure>
Line 274: Line 278:
 
<figure data-ref="8" align = "center">
 
<figure data-ref="8" align = "center">
 
<img class="playGif ui big centered image" src="//2016.igem.org/wiki/images/c/cc/T--Slovenia--1dThumbnail.png" data-alt="//2016.igem.org/wiki/images/7/7b/T--Slovenia--Us1d.gif">
 
<img class="playGif ui big centered image" src="//2016.igem.org/wiki/images/c/cc/T--Slovenia--1dThumbnail.png" data-alt="//2016.igem.org/wiki/images/7/7b/T--Slovenia--Us1d.gif">
<figcaption>The vertical cut of the acoustic pressure through the focal point. The waves that travel from the right to the left, are on the right side slightly deformed due to wave interferences from two separate probes.
+
<figcaption>The vertical cut of the acoustic pressure through the focal point. The waves that travel from the right to the left, are slightly deformed on the right side due to the wave interferences from two separate probes.
 
</figcaption>
 
</figcaption>
 
</figure>
 
</figure>
Line 282: Line 286:
 
<h2><span id="conclusion" class = "section"> &nbsp; </span>Conclusion and outlook</h2>
 
<h2><span id="conclusion" class = "section"> &nbsp; </span>Conclusion and outlook</h2>
 
<p>
 
<p>
We generated a model for the propagation of ultrasound waves through tissue. In our case a transversal cut of the middle head area was taken. Two probes were adjusted in such a manner that focusing on small area was obtained.  
+
We generated a model for the propagation of the ultrasound waves through tissue. In our case a transversal cut of the middle head area was taken. Two probes were adjusted in such a manner that the focusing on small area was obtained.  
With this model we can confirm the potential of the ultrasound as a platform for therapeutic applications, but for more advanced use the software tools needs to be further developed. That tool would include automatic tissue segmentation from patient medical images, computing propagation of ultrasound waves in 3D aimed to assist in experts in the probe positioning.  
+
With this model we can confirm the potential to use the ultrasound as a platform for therapeutic applications, but for more advanced use the software tools needs to be further developed. Further development will include automatic tissue segmentation from patient medical images, computing propagation of ultrasound waves in 3 dimensions aimed to guide the experts with the probe positioning.  
 
The low intensity ultrasound image could be used to receive the feedback of the sonogram of the tissue for each probe that could be used to drive ultrasound stimulation for cell activation in the desired area. It is likely that the specific shape of the stimulated tissue could be selected rather than just a single focal point.
 
The low intensity ultrasound image could be used to receive the feedback of the sonogram of the tissue for each probe that could be used to drive ultrasound stimulation for cell activation in the desired area. It is likely that the specific shape of the stimulated tissue could be selected rather than just a single focal point.
 
</p>
 
</p>

Revision as of 01:03, 15 October 2016

Ultrasound propagation modeling

  Ultrasound propagation modeling

Ultrasound are sound waves with frequencies higher than upper audible limit of human hearing, i.e. higher than 20 kHz. In the frequency range between 0.8 and 5 Mhz, the sound wave length is between 2 and 0.3 mm. Ultrasound is mainly used for diagnostic purposes. Unlike light ultrasound can easily penetrate the tissue and is at those intensities completely harmless. It is therefore used also in prenatal diagnostics where non-invasivness is of vital importance. Short wavelengths additionally enable us to create small regions of high intensity focused ultrasound waves at the focal point, which can be used for therapeutic purposes escoffre2016therapeutic for example for the tissue ablation. High intensity focused ultrasound has been already used in thermal ablation therapies escoffre2016therapeutic. In vital organs like brain it is particularly important to focus high intensity ultrasound beams at the small targeted structure in order to avoid unwanted tissue damage.

Based on our improvement of the ultrasound responsiveness of the cells it would be feasible to introduce a genetic device into the target tissue and then selectively activate only specific cells by using focused ultrasound, causing a sufficient intensity of the acoustic pressure. This would for example enable the stimulation of neurons in the selected brain section to achieve non-invasive deep brain stimulation or to stimulate cells to produce different hormones.

For this purpose we designed a model of the ultrasound propagation. The model can guide us in the process of the ultrasound device calibration with the potential to use multiple ultrasound probes.

  Sound modeling with wave equation

The code for the ultrasound propagation model is written in C++ programming language with OpenGL library. The model was parallelized using OpenMP to take advantage of multi-core processor architecture and to achieve better performance. Source code is available on GitHub.


Sound is a vibration that propagates as a mechanical wave of pressure and displacement through the medium. The speed of its propagation also depends on the properties of the medium. This means that the speed of sound varies greatly between different types of tissues azhari2010basics. The speed of sound propagation in different tissue in comparison to its propagation through air is represented in (2).

Name Speed (m/s)
Skin 1730
White matter 1570
Grey matter 1570
Skull 4080
Cerebrospinal Fluid 1500
Air 343


In order to achieve a realistic simulation of the sound propagation through brain an MR image represented in 3 was used mollerpocket. Furthermore, we performed the tissue segmentation with the aid of medical experts, i.e. our team members, students of medicine (Kosta, Samo and Nina) (4).

An MR of transversal cut at the middle head area.
The segmentation of head section, where the green color represents skin, blue color represents bone, cyan color represents the cerebrospinal fluid, dark grey color represents grey brain matter and light grey color represents white brain matter. While the speed of sound does not vary much between dark and white grey matter it is sufficient to model only brain matter in general.

The representation of a Gaussian beam function in two dimensions using a probe with a focus of 7 cm. Although focusing is not good, one can notice the elongation of a focused area. This is the case even in simulation with higher frequencies. This suggests that efficient focusing in the tissue requires at least two probes.

The probes in our model are capable of emitting sound waves at frequencies ranging from 0.5 Mhz to 5 Mhz at acoustic pressure from 10 kPa to 100 kPa. The focused probes that we used have focal length of 7 cm. Besides focused probes we also modeled unfocused probes. Both types of probes have an aperture of 4.4 cm. In general propagation of sound from the focused probe can be approximated with an analytic function of a Gaussian beam (6), but this representation fails when we want to model wave interferences from multiple probes. For such cases wave equation model needs to be established.

Acoustic wave equation is a second-order linear partial differential equation that governs the propagation of acoustic waves through the medium. The general form of the equation is: \begin{equation} \frac{\partial^2 p}{\partial t^2} = c^2(\nabla^2 p) \end{equation} where $c$ is speed of sound in the medium, $p$ is acoustic pressure (the deviation from ambient pressure) and $\nabla^2$ is Laplacian operator (sum of second order partial derivatives with respect to each independent variable). In two dimensional Cartesian coordinate system we get the following equation: \begin{equation} \frac{\partial^2 p}{\partial t^2} = c^2(\frac{\partial^2 p}{\partial x^2} + \frac{\partial^2 p}{\partial y^2}) \end{equation} While wave equation cannot be solved analytically, one can approximate it with finite difference method. Let's presume we want to approximate the solution on a squared area. First we need to discretize the area to obtain the grid of evenly distributed points $(x_{i}, y_{j})$, $i,j = 1,...,n$. The Laplacian operator can now be approximated as: \begin{equation} \nabla^2 p_{i, j} \approx \frac{1}{h^2}(p_{i + 1, j} + p_{i-1, j} + p_{i, j + 1} + p_{i, j - 1} - 4p_{i,j}) \end{equation} where $h$ is Euclidean distance between two adjacent points. Since the frequencies between 0.8 and 5 Mhz correspond to the wavelength between 2 and 0.3 mm, $h$ does not need to be smaller than 0.3 mm. We now obtain a $n*n$ system of the second order ordinary differential equations: \begin{equation} \ddot{p}_{i, j} = \frac{c^2}{h^2}(p_{i + 1, j} + p_{i-1, j} + p_{i, j + 1} + p_{i, j - 1} - 4p_{i,j}) \end{equation} These equation can be simplified to the first order differential equations with the introduction of a new variable that represents the speed: $(v_{i, j} = \dot{p}_{i, j})$. The new system now has the following form: \begin{equation} \begin{aligned} \dot{p}_{i, j} = v_{i, j} \\ \dot{v}_{i, j} = \frac{c^2}{h^2}(p_{i + 1, j} + p_{i-1, j} + p_{i, j + 1} + p_{i, j - 1} - 4p_{i,j}) \end{aligned} \end{equation} The dispersion of the waves is already included in the wave equation. However, the absorption of sound waves in tissue is not included. The absorption can be approximated with the introduction of the attenuation coefficient $k$. We fitted attenuation coefficient to experimental data sprawls1989ultrasound to obtain, $k = 16000$ for soft tissue and $k = 160000$ for bone tissue. The final equation now has the form: \begin{equation} \dot{v}_{i, j} = \frac{c^2}{h^2}(p_{i + 1, j} + p_{i-1, j} + p_{i, j + 1} + p_{i, j - 1} - 4p_{i,j}) - k*v_{i,j} \end{equation}

A flowchart representing an iterative computation of wave equation.

Finally we can solve the given system with iterative numeric methods such as Euler's method or Runge-Kutta method. The most widely known method of the Runge-Kutta family is RK4, which was also used in our model. While RK4 introduces some computational overhead it also significantly increases the numerical stability of the system in comparison to the Euler's method. The most basic steps used for the calculation of ultrasound propagation are displayed in (5).

We model a propagation of the ultrasound waves on a 500 x 500 grid, where distances between points are exactly 0.3 cm. This translates to a stimulated area of 15 by 15 cm. The model computes propagation of waves in 2 dimensions. While the computational complexity of calculating the solutions of wave equation in 3 dimensions is asymptotically much higher than in 2 dimensional space, it is unnecessary to demonstrate the ability to focus the ultrasound by modulation of the intensity, frequency and geometry of the ultrasound probes. However, in 3 dimensional space the intensity in the focal point should increase, since addition of sound waves is coming from all directions not just from left and right. Three or more probes could be combined to define the focal point in 3D. In our model it is also possible to observe the main sound characteristics such as the attenuation, reflection and occlusion. Probes are modeled as the set of finite elements. The pressure of every finite element on the probe is set according to sine function with the selected amplitude and frequency, thus every finite element acts like independent source of the acoustic pressure.

  Results

Simulations computed with our model (7) clearly show that it is possible to target small regions of brain tissue. We can also observe the one dimensional cut of acoustic pressure, where focusing is even more evident (8). The probe on the right is slightly displaced due to the asymmetry of the tissue. This clearly shows that models need to be applied to calculate the optimal position of ultrasound probes. Such software will include automatic tissue segmentation, modeling of propagation of ultrasound waves and will assist experts in probe positioning. Our model is a step in that direction, since it can be used as a tool for positioning the probes. In the model that we generated focused and unfocused probes can be added or removed and positioned. Additionally probe's acoustic pressure and frequency can be set.

The propagation of ultrasound waves through brain tissue as computed with our model. One can observe the small focused area in the middle of the brain (Fornix). We can also detect green specks in the bone region, which are caused by the reflection of the sound waves. Since the speed of sound in the bone is much higher than the speed in soft tissue, the acoustic wavelengths in the bone are increased.
The vertical cut of the acoustic pressure through the focal point. The waves that travel from the right to the left, are slightly deformed on the right side due to the wave interferences from two separate probes.

  Conclusion and outlook

We generated a model for the propagation of the ultrasound waves through tissue. In our case a transversal cut of the middle head area was taken. Two probes were adjusted in such a manner that the focusing on small area was obtained. With this model we can confirm the potential to use the ultrasound as a platform for therapeutic applications, but for more advanced use the software tools needs to be further developed. Further development will include automatic tissue segmentation from patient medical images, computing propagation of ultrasound waves in 3 dimensions aimed to guide the experts with the probe positioning. The low intensity ultrasound image could be used to receive the feedback of the sonogram of the tissue for each probe that could be used to drive ultrasound stimulation for cell activation in the desired area. It is likely that the specific shape of the stimulated tissue could be selected rather than just a single focal point.

  References