Difference between revisions of "Tracks/Measurement/Interlab study/Flow Cytometry Overview"

(Created page with "{{Mobile}} <html> <div class="oneColumn"> <h2>Measurement with Flow Cytometry</h2> <p>This is a general guide for setting up your cells for flow cytometry readings in absolut...")
 
Line 1: Line 1:
 
{{Mobile}}
 
{{Mobile}}
 
<html>
 
<html>
 +
<div class="oneColumn alert_box">
 +
<center>This page is under active development and is in draft form.</center>
 +
</div>
 +
<br><br><br><br><br>
 +
 
<div class="oneColumn">
 
<div class="oneColumn">
 
<h2>Measurement with Flow Cytometry</h2>
 
<h2>Measurement with Flow Cytometry</h2>
Line 10: Line 15:
 
<li>A flow cytometer with a channel configured for measurement of fluorescein (FITC) or GFP.  This channel will typically have a 488nm laser an a 530/30 filter, but the details may vary.</li>
 
<li>A flow cytometer with a channel configured for measurement of fluorescein (FITC) or GFP.  This channel will typically have a 488nm laser an a 530/30 filter, but the details may vary.</li>
 
<li>Fluorescent calibration beads that have been calibrated for Molecules of Equivalent FLuorescein (MEFL) or Molecules of Equivalent GFP (MEGFP). If available, we recommend using SpheroTech Rainbow Calibration Particles RCP-30-5A, as that is what the accompanying spreadsheet has been designed for. </li>
 
<li>Fluorescent calibration beads that have been calibrated for Molecules of Equivalent FLuorescein (MEFL) or Molecules of Equivalent GFP (MEGFP). If available, we recommend using SpheroTech Rainbow Calibration Particles RCP-30-5A, as that is what the accompanying spreadsheet has been designed for. </li>
 +
<br><br>
  
 
+
<b>Important!</b> If you have used a flow cytometer to measure GFP for the InterLab, please fill out the following Google Form to the best of your ability:
 +
<br><br>
 +
<a href="URL">
 +
    <div class="button">
 +
      Flow Cytometer Form
 +
    </div>
 +
</a>
 
</html>
 
</html>
  
 
{{2016Bottom}}
 
{{2016Bottom}}

Revision as of 19:48, 26 April 2016

This page is under active development and is in draft form.





Measurement with Flow Cytometry

This is a general guide for setting up your cells for flow cytometry readings in absolute units. These steps and questions are meant to provide a general protocol and we ask that you follow them to the best of your ability.

In order to carry out this measurement protocol, you will need:

  • A flow cytometer with a channel configured for measurement of fluorescein (FITC) or GFP. This channel will typically have a 488nm laser an a 530/30 filter, but the details may vary.
  • Fluorescent calibration beads that have been calibrated for Molecules of Equivalent FLuorescein (MEFL) or Molecules of Equivalent GFP (MEGFP). If available, we recommend using SpheroTech Rainbow Calibration Particles RCP-30-5A, as that is what the accompanying spreadsheet has been designed for.


  • Important! If you have used a flow cytometer to measure GFP for the InterLab, please fill out the following Google Form to the best of your ability:

    Flow Cytometer Form