Measurements were then taken each hour for 6 hours by pipetting 100µl of each culture into the 96 well plate according to the iGEM layout for Abs600 and Fluorescence measurement and using the calibrated Tecan spectrometer.</p>
 
Measurements were then taken each hour for 6 hours by pipetting 100µl of each culture into the 96 well plate according to the iGEM layout for Abs600 and Fluorescence measurement and using the calibrated Tecan spectrometer.</p>
  
<p id="pp"> The protocol was iporved by using a latin rectangle arrangement in another 96 well plate. A lab robot was used to pipette out the corresponding cultures to their wells according to our preset programme linked to a descrambling spreadsheet. The measurements were taken using the same calibration settings as before on the Tecan plate reader every hour for 6 hours. The plate was placed into mini vibrating incubator at 37°C between plate readings. A scratch was noticed on the plate lid and was replaced. This lid was cold compared to the incubated plate and so condensation formed this could have affected the results. Placed in incubator for 1.46 mins to warm up.</p>
+
<p id="pp"> The protocol was improved by using a latin rectangle arrangement in another 96 well plate. A lab robot was used to pipette out the corresponding cultures to their wells according to our preset programme linked to a descrambling spreadsheet. The measurements were taken using the same calibration settings as before on the Tecan plate reader every hour for 6 hours. The plate was placed into mini vibrating incubator at 37°C between plate readings. A scratch was noticed on the plate lid and was replaced. This lid was cold compared to the incubated plate and so condensation formed this could have affected the results. Placed in incubator for 1.46 mins to warm up.</p>
  
 
<p id="pp">The Latin rectangle is designed so that no sample gets pipetted more than once in any row or column. The order in which the samples get arranged was worked out using the random number function of Microsoft Excel. Sterile LB was loaded into peripheral wells to lessen edge effects which can skew results due to high evaporation at the periphery. These adaptations aim to provide more accurate data.</p>
 
<p id="pp">The Latin rectangle is designed so that no sample gets pipetted more than once in any row or column. The order in which the samples get arranged was worked out using the random number function of Microsoft Excel. Sterile LB was loaded into peripheral wells to lessen edge effects which can skew results due to high evaporation at the periphery. These adaptations aim to provide more accurate data.</p>