Difference between revisions of "Team:TU Delft/Model/Q1"

Line 34: Line 34:
 
                     <h2 class="title-style-2 col-md-offset-1">Introduction</h2>                                       
 
                     <h2 class="title-style-2 col-md-offset-1">Introduction</h2>                                       
 
                     <div class="col-md-10 col-md-offset-1">
 
                     <div class="col-md-10 col-md-offset-1">
<p>In order to get lasing inside our bacteria we constructed an optical cavity inside and around the bacteria. An optical cavity is an arrangement of optical components which traps the light inside in a closed path (standing waves), where the light can resonate.  For most normal lasers this is accomplished by two mirrors (figure 1A). In our project PHB granules are formed inside cells and by total internal reflection the light should be trapped inside them. Another way to form an optical cavity is by encapsulation of the bacteria in a material with a higher refractive index than the inside of the cell. This can be achieved by the enzyme silicatein, which polymerizes monomers such as silicic acid and tin dioxide, creating the desired reflective layer (figure 1B). In order to trap the light inside these cavities it is necessary that the light ‘fits’ inside. Therefore standing waves have to be formed within the cavity. Here we will determine what the minimal required size of these cavities is to fit exactly one wavelength inside. This will not give us a definite answer whether we will get lasing, but a very strict lower bound of the required cavity size. </p>
+
<p>In order to get lasing inside our bacteria we constructed an optical cavity inside and around the bacteria. An optical cavity is an arrangement of optical components which traps the light inside in a closed path (standing waves), where the light can resonate.  For most normal lasers this is accomplished by two mirrors (figure 1A). In our project PHB granules are formed inside cells and by total internal reflection the light should be trapped inside them. Another way to form an optical cavity is by encapsulation of the bacteria in a material with a higher refractive index than the inside of the cell. This can be achieved by the enzyme silicatein, which polymerizes monomers such as silicic acid and tin dioxide, creating the desired reflective layer (figure 1B). In order to trap the light inside these cavities it is necessary that the wavelength of light ‘fits’ inside. Therefore standing waves have to be formed within the cavity. Here we will determine what the minimal required size of these cavities is to fit exactly one wavelength inside. This will not give us a definite answer whether we will get lasing, but a very strict lower bound of the required cavity size. </p>
 
<figure>
 
<figure>
 
<img src = "https://static.igem.org/mediawiki/2016/1/1e/%60T--TU_Delft--modeling1.png" alt="">   
 
<img src = "https://static.igem.org/mediawiki/2016/1/1e/%60T--TU_Delft--modeling1.png" alt="">   

Revision as of 14:35, 17 October 2016

iGEM TU Delft

Modeling

Question 1:

How can light resonate in the cell and what is the minimal size of the cavity in order to fit light inside it?

Introduction

In order to get lasing inside our bacteria we constructed an optical cavity inside and around the bacteria. An optical cavity is an arrangement of optical components which traps the light inside in a closed path (standing waves), where the light can resonate. For most normal lasers this is accomplished by two mirrors (figure 1A). In our project PHB granules are formed inside cells and by total internal reflection the light should be trapped inside them. Another way to form an optical cavity is by encapsulation of the bacteria in a material with a higher refractive index than the inside of the cell. This can be achieved by the enzyme silicatein, which polymerizes monomers such as silicic acid and tin dioxide, creating the desired reflective layer (figure 1B). In order to trap the light inside these cavities it is necessary that the wavelength of light ‘fits’ inside. Therefore standing waves have to be formed within the cavity. Here we will determine what the minimal required size of these cavities is to fit exactly one wavelength inside. This will not give us a definite answer whether we will get lasing, but a very strict lower bound of the required cavity size.

Figure 1: (A) Conventional laser. In a conventional laser an optical cavity is the space between two mirrors opposite to each other. The optical cavity is filled with a gain medium composed of molecules that can get excited by an external excitation source such as light or electric current. (B) For biolasers we use use a reflective surface instead of mirrors. As an excitation source we use a laser which can excite the gain medium. The gain medium we use are fluorophores.

Whispering Gallery Modes

Figure 2: Circular resonation of light in a whispering gallery mode resonator.

In both methods of capturing light (PHB granules and covering the cell with silica), the light will become trapped by whispering gallery mode (WGM) resonance (Humar et al., 2015). WGM resonance is the phenomenon where waves travel around a concave surface in a closed path (figure 2). Every time the wave hits the surface, total internal reflection occurs. When light hits a interface between two materials the light gets refracted as in figure 3A. If the angle \(\theta_i\) is large enough, the lights does not go trough the interface and gets reflected as in figure 3B. Whispering gallery mode resonance was first explained by Lord Rayleight in the St Paul’s Cathedral for sound waves. When you whisper to the wall of the cathedral the sound waves were able to travel along the wall and a person at the other side of the cathedral could hear it. However someone standing in the middle of the cathedral was not able to hear the whispering. Therefore this phenomenon was called whispering gallery mode resonance. (Rayleigh et al., 1877)

Figure 3: (A) Refraction of the light due to the interface of two materials. (B) When the angle of incidence becomes larger than in 3A, it reaches the critical angle. At the critical angle the out-coming light travels parallel to the interface. (C) If the incidence angle becomes larger than the critical angle total internal reflection can take place and the lights get reflected.

It is important that the waves follow a closed path forming a polygon so that constructive interference takes place. Constructive interference occurs when two waves travel in phase so that their amplitudes add up (figure 4). We need constructive interference so that every cycle in the resonater adds to the constructive interference. To make sure the waves travel in phase so that constructive interference can take place, the optical path length (OPL) is required to be an integer number of wavelengths (equation 1). In equation 1 n is the number of sides of length l, and m an integer number of wavelengths \(\lambda\).

$$OPL=n\cdot l = m\lambda$$
Figure 4: Interference of light. The amplitudes of waves that that are at the same point in time and space add up together.

PHB Granules

For intracellular lasers, oil droplets have been used before as an optical cavity (Humar et al., 2015). In our project we use PHB granules inside the E. coli instead of oil droplets as an optical cavity. This PHB granule will then be stained with the fluorescent dye Nile Blue with an emission maximum of 580 nm (Kitamura et al., 1994) to create the gain medium.

In order to get WGM resonance the light beam has to be reflected by total internal reflection every time it hits the surface. Therefore the light beam has to approach the surface at a minimal angle larger than the critical angle. From Snell’s law (equation 2) we can compute the critical angle (Hecht, 2001) where the incoming light is refracted to have an outgoing angle of exactly 90 degrees (figure 3C). In equation 2 and 3, \(n_1\) and \(n_2\) are the refractive indices of the materials at the interface.

$$n_1 sin(\theta_{i}) = n_2 sin(\theta_{f})$$ $$\theta_{c} = \arcsin\Big(\frac{n_2}{n_1}\sin\big(\frac{\pi}{2}\big)\Big)=\arcsin\Big(\frac{n_2}{n_1}\Big)$$

The outgoing light in total internal reflection should have an angle \(\theta_f>\theta_c\) to be reflected. When we look into geometrical optics the path of the light is as shown in figure 5. Since we want a closed optical path (polygon), we have an integer number of sides on the polygon. Using equation 4 from we can determine the number of sides \(n_{sides}\) of the polygon as in equation 5.

Figure 5: The path of the light in a PHB granule. Using trigonometry we can determine the angles \(\phi\) and \(\theta\).
$$\phi = \pi - 2\theta_{f}$$ $$n_{sides} = \frac{2\pi}{\phi} = \frac{2\pi}{\pi-2\theta_{f}}$$

We can calculate the number of sides by using the reflected angle \(\theta_f\) in equation 4 and round the \(n_{sides}\) up to an integer. This will give us the smallest polygon possible for WGM. We can then calculate the smallest possible value of \(\theta_f\) to get total internal reflection with a closed optical path as in equation 6.

$$\theta_f = \frac{\pi}{2}-\frac{\pi}{round(n_{sides})} $$

Now that we know how many sides the polygon has, we can compute the minimal size for the granule sphere so that an integer number of wavelengths fit into the optical path length:

$$m\lambda = n_{sides}l$$ $$l = 2Rcos(\theta_{f})$$

We suggest that at least one wavelength should fit into \(l\) ( \(l=\lambda\) ) so that the waves can get trapped. Therefore the minimum size of the granule should be as in equation 9:

$$R = \frac{\lambda}{2\cos(\theta_{f})}$$

Results

For PHB granules the refractive index at a wavelength of 580 nm is \(n_{PHB} = 1.468\) (Huglin et al., 1991). The refractive index of cytosol is \(n_{cytoplasm} = 1.37\) (Liang et al., 2007). Putting these values into our model, we find that the minimal size of the PHB granules is \(1.7\mu m\) (figure 6). This is quite a bit larger than we expect the granules to be since the size of E. coli is only \(1-2 \mu m\) long and the granules will not fill the entire bacterium.

Figure 6: The path of light in a PHB granule. The minimal diameter of the granule is \(d=1.7\mu m\).

Silica covered cells

Since the size of the PHB granules that can be grown inside an E. coli bacterium was expected to be smaller than the required size for lasing, we investigated the option of making a biolaser out of the entire cell. Therefore we encapsulated the cell with a layer of biosilica and tin dioxide. The gain medium in this method is provided by fluorophores which we expressed in the cytosol of the cell. To determine the minimal size in this case the calculation was a bit more tricky than for the PGB granules, since we had to take the layer into account and the optical path has a star-like shape (figure 3A) .

Figure 7: The path of light in a cell covered with a layer of biosilica or tin dioxide. The optical path has a star like shape.

The critical angle can again be computed by equation 3, where \(n_1\) is the refractive index of the layer \(n_f\), and \(n_2\) is the refractive index of the buffer outside the cell \(n_b\). When the angle is slightly larger than the critical angle we have total internal reflection where the outgoing angle is equal to the incoming angle, therefore we may set \(\alpha = \theta_c\). In this model we will neglect the curvature of the surface which means that we can also set \(\theta_i=\alpha\). Using Snell’s Law (equation 2) again we can compute the outgoing angle \(\theta_0\) (equation 10) where \(n_f\) is the refractive index of the layer and \(n_c\) the refractive index of the cytosol.

$$\theta_0 = asin\Big(\frac{n_f}{n_c} sin(\alpha)\Big) $$

From \(\theta_0\) we can easily determine the angle \( \phi \) since all the angles in a triangle add up to \(\pi\) (equation 11).

$$\phi = \pi-2 \theta_0 = \pi-2\arcsin\Big(\frac{n_f}{n_c} sin(\alpha)\Big)$$

Here the path of the light is star-shaped and the \( OPL=k_{sides}\lambda\). Furthermore we will assume that the total path length per side is minimally \(\lambda\) and that one side is taken as the path from point A to D. The optical path length per side is given as \(OPL_{side}=2\cdot x+l\geq\lambda\). \(X\) and \(l\) can be determined as in equation 12. From equation 12 the minimal radius can be determined for the criteria where \(OPL_{sides} = \lambda\) (equation 13).

$$\left.\begin{matrix} OPL_{sides} =2x+l\geq \lambda \\ x=\frac{t}{\cos\alpha}\\ l =2R\cos\theta_o \end{matrix}\right\} OPL_{sides} = \lambda = \frac{2t}{\cos\alpha}+2R \cos\theta_o =\frac{2t}{\cos\alpha}+2R \sqrt{1-(\frac{n_f}{n_c}\sin\alpha)^2}\geq\lambda $$ $$ R_{min} = \frac{\lambda-\frac{2t}{\cos\alpha}}{2\cos\theta_o}$$

Using the minimal radius of R we can determine the angle \(\psi\) as in equation 14.

$$ \psi=2\arcsin(\frac{t \tan\alpha}{R_{min}})$$

Using \(\psi\) and \(\phi\) we can determine the minimal number of sides of the optical path (equation 15).

$$k_{sides} = \frac{2\pi}{\psi+\phi}$$

In equation 15, \(k_{sides}\) has to be an integer to have a closed optical path. Taken together the constraints as in equation 16 we get an equation for \(\phi\) and \(\psi\) as a function of \(\alpha\).

$$\left.\begin{matrix} \frac{2\pi}{k_{sides}}=\phi+\psi\\ \phi = \pi-2\arcsin(\frac{n_f}{n_c}\sin\alpha)\\ \psi = 2\arcsin(\frac{t\tan\alpha}{R_{min}})\\ OPL_{sides}=2x+l \rightarrow R_{min} = \frac{\lambda-\frac{2t}{\cos\alpha}}{2\sqrt{1-(\frac{n_f}{n_c}\sin\alpha)^2}} \end{matrix}\right\} \frac{2\pi}{k_{sides}}=\pi-2\arcsin(\frac{n_f}{n_c}\sin\alpha)+2\arcsin(\frac{2t\sin\alpha\sqrt{1-(\frac{n_f}{n_c}\sin\alpha)^2}}{\lambda\cos\alpha-2t})$$

Solving equation 16 for \(\alpha\) and using this in the equation for the radius results in the minimal radius required for WGM in a cell covered with a layer of biosilica or tin dioxide.

Results

Using the model described above we determined the minimal radius of a cell covered with polysilica and tin dioxide to create a cavity that allows for whispering gallery modes. The refractive index of polysilica is 1.47 (Liang et al., 2007). The refractive index of tin dioxide is 2 (Pradyot, 2003). For both cases we calculated the minimal radius assuming the thickness of the layer to be 50 nm and a wavelength of 509 nm, the emission wavelength of GFP. From our model we found a minimal diameter of \(1.2 \mu m\) and \(1.6 \mu m\) (figure 8) for polysilica and tin dioxide respectively. These sizes are comparable to the size of a bacterium, so whispering gallery modes should in principle be possible inside a covered cell. However, we made a number of simplifications in our model that will in practice probably prevent the system from lasing at this minimum scale. First, we did not take the polarization of the light into account. Second, the length scales we work with here are only about twice the wavelength, and the thickness of the boundary layer is much smaller than the wavelength. A more accurate description of what is happening within the cell would require us to work in the thin layer limit (known as Mie theory) as we do in Q4. There we calculate the quality factor for the cavity, which indicates how well the light can be trapped within the structure. Third, in this model we only determined whether light waves will fit into the cavity, in Q3 we will also determine whether lasing can take place with the size of the cell and the reflectivity of polysilica and tin dioxide.

Figure 8: (A) For a cell covered in a 50 nm polysilica the minimal diameter is \(1.2\mu m\). (B) For a cell covered in tin dioxide the minimal diameter is \(1.6\mu m\).
  1. Aizenberg, J., Sundar, V. C., Yablon, A. D., Weaver, J. C., & Chen, G. (2004). Biological glass fibers: Correlation between optical and structural properties. Proceedings of the National Academy of Sciences of the United States of America, 101(10), 3358–3363. https://doi.org/DOI 10.1073/pnas.0307843101
  2. Hecht, E. (2001). Optics 4th edition. Optics 4th Edition by Eugene Hecht Reading MA Addison Wesley Publishing Company 2001. https://doi.org/10.1119/1.3274347
  3. Huglin, M. B., & Radwan, M. A. (1991). Behaviour of poly(β-hydroxybutyric acid) in dilute solution. Polymer International, 24(2), 119–123. https://doi.org/10.1002/pi.4990240210
  4. Humar, M., & Yun, S. H. (2015). Intracellular microlasers. Nature Photonics, 9(9), 572–576. https://doi.org/10.1038/nphoton.2015.129
  5. Kitamura, S., & Doi, Y. (1994). Staining method of poly(3-hydroxyalkanoic acids) producing bacteria by nile blue. Biotechnology Techniques, 8(5), 345–350. https://doi.org/10.1007/BF02428979
  6. Liang, X. J., Liu, A. Q., Lim, C. S., Ayi, T. C., & Yap, P. H. (2007). Determining refractive index of single living cell using an integrated microchip. Sensors and Actuators A: Physical, 133(2), 349-354.
  7. Patnaik, P. (2003). Handbook of Inorganic Chemicals. Ebook. Retrieved from ftp://pvictor.homeftp.net/public/Sci_Library/Chem Library/Handbooks/Patnaik P. Handbook of inorganic chemicals (MGH, 2003)(T)(1125s).pdf
  8. Strutt, J. W., & Rayleigh, B. (1877). The Theory of Sound. Nature (Vol. 1). https://doi.org/10.1038/058121a0
  9. Wyatt, P. J. (1968). Differential Light Scattering: a Physical Method for Identifying Living Bacterial Cells. Applied Optics, 7(10), 1879. https://doi.org/10.1364/AO.7.001879