Difference between revisions of "Team:Hong Kong HKUST/Parts Improvement"

Line 52: Line 52:
 
<p>The 2011 Uppsala Sweden iGEM team had previously submitted characterization data for parts BBa_K592023 and BBa_K592024. However, we discovered that they did not put a terminator after the mTagBFP CDS. We wondered if the observed fluorescence outputs will be different with versus without a terminator. Therefore, we decided to perform an experiment for comparison. The experimental results showed that the observed fluorescence levels were lowered without a terminator.
 
<p>The 2011 Uppsala Sweden iGEM team had previously submitted characterization data for parts BBa_K592023 and BBa_K592024. However, we discovered that they did not put a terminator after the mTagBFP CDS. We wondered if the observed fluorescence outputs will be different with versus without a terminator. Therefore, we decided to perform an experiment for comparison. The experimental results showed that the observed fluorescence levels were lowered without a terminator.
 
<br><br>Given our results, we would like to caution future users in referencing the relative promoter strengths reported by Uppsala Sweden 2011, as their measured expression levels, generated by parts without a terminator, may not fully represent the true strength of the tested promoters.</p>
 
<br><br>Given our results, we would like to caution future users in referencing the relative promoter strengths reported by Uppsala Sweden 2011, as their measured expression levels, generated by parts without a terminator, may not fully represent the true strength of the tested promoters.</p>
<br><br><br>&emsp;&emsp;&emsp;&emsp;&emsp;&emsp;
+
<br><br><br>&emsp;&emsp;&emsp;&emsp;&emsp;&emsp;&emsp;
<img src= "https://static.igem.org/mediawiki/2016/4/48/Team--Hong_Kong_HKUST--Parts_Improvement.png" style="width:1000px;height:800px">
+
<img src= "https://static.igem.org/mediawiki/2016/4/48/Team--Hong_Kong_HKUST--Parts_Improvement.png" style="width:800px;height:640px"><br><br>
 
<figp><b>Figure 1. Comparison of the expression levels of a BFP generator with and without a terminator.</b> (a) Circuit diagram illustrates experimental setup of the experiment harboring BBa_B0032. (b) Experimental results of the experiment harboring BBa_B0032. (c) Circuit diagram illustrates experimental setup of the experiment harboring BBa_B0034. (d) Experimental results of the experiment harboring BBa_B0034. Error bars represent SEM of 3 independent experiments on 3 different days.</figp>
 
<figp><b>Figure 1. Comparison of the expression levels of a BFP generator with and without a terminator.</b> (a) Circuit diagram illustrates experimental setup of the experiment harboring BBa_B0032. (b) Experimental results of the experiment harboring BBa_B0032. (c) Circuit diagram illustrates experimental setup of the experiment harboring BBa_B0034. (d) Experimental results of the experiment harboring BBa_B0034. Error bars represent SEM of 3 independent experiments on 3 different days.</figp>
 
</div>
 
</div>

Revision as of 17:20, 20 September 2016

Navigation

Before boarding, go check out below some tricks that will be useful in the course of your journey!


trafficlight

Trick 1 - The Mode Switcher

The mode switcher, in analogue to a traffic light, combines 3 different interfaces into one powerful device switchable to one another.

Red: Default mode (Veteran, no support needed!)
Yellow: Tour mode (Summary of each and every page in one single map)
Green: Construct mode (A reference diagram of our genetic construction)

TourMode Home About Project Achievements Future_Plan Human Practices Modelling Lab Interlab Collaboration

Welcome to HKUST 2016 iGEM team - Troika!! We made a simple tour to make navigating our website a breeze! Follow us!

Improvements on BBa_K592023 and BBa_K592024

(Blue Fluorescent Protein mTagBFP generators)

The 2011 Uppsala Sweden iGEM team had previously submitted characterization data for parts BBa_K592023 and BBa_K592024. However, we discovered that they did not put a terminator after the mTagBFP CDS. We wondered if the observed fluorescence outputs will be different with versus without a terminator. Therefore, we decided to perform an experiment for comparison. The experimental results showed that the observed fluorescence levels were lowered without a terminator.

Given our results, we would like to caution future users in referencing the relative promoter strengths reported by Uppsala Sweden 2011, as their measured expression levels, generated by parts without a terminator, may not fully represent the true strength of the tested promoters.




       

Figure 1. Comparison of the expression levels of a BFP generator with and without a terminator. (a) Circuit diagram illustrates experimental setup of the experiment harboring BBa_B0032. (b) Experimental results of the experiment harboring BBa_B0032. (c) Circuit diagram illustrates experimental setup of the experiment harboring BBa_B0034. (d) Experimental results of the experiment harboring BBa_B0034. Error bars represent SEM of 3 independent experiments on 3 different days.