Difference between revisions of "Team:Ionis Paris/Proof"

Line 44: Line 44:
 
<p> The toluene is known to be a volatile compound. This is why we decided to determine its rate of evaporation before proceeding to any subsequent manipulation with toluene. This will determine the care taken when handling it as well as the time the stock solution will be kept. <br/>
 
<p> The toluene is known to be a volatile compound. This is why we decided to determine its rate of evaporation before proceeding to any subsequent manipulation with toluene. This will determine the care taken when handling it as well as the time the stock solution will be kept. <br/>
 
1mL of pure toluene (867g/L, 244511 Sigma-Aldrich) was added  in a 1.5mL Eppendorf tube. The tube was left open under a chemical hood and its weight was calculate every 30 minutes. </p>
 
1mL of pure toluene (867g/L, 244511 Sigma-Aldrich) was added  in a 1.5mL Eppendorf tube. The tube was left open under a chemical hood and its weight was calculate every 30 minutes. </p>
 
  
 
<h3><font color = "A2233C">Results</font></h3>
 
<h3><font color = "A2233C">Results</font></h3>
Line 175: Line 174:
 
<p><i> Figure 2 : Bioluminescence intensity expressed in RLU of LB and LB with toluene at 10mg/L. Mann whitney statistical test was performed to asses the effect of toluene on LB auto-bioluminescence (ns: non significant). </i></p>
 
<p><i> Figure 2 : Bioluminescence intensity expressed in RLU of LB and LB with toluene at 10mg/L. Mann whitney statistical test was performed to asses the effect of toluene on LB auto-bioluminescence (ns: non significant). </i></p>
  
 
+
<br/>
 
<b><font color = "D32C50"> Bacteria E.coli have little auto-bioluminescence </font> </b>
 
<b><font color = "D32C50"> Bacteria E.coli have little auto-bioluminescence </font> </b>
  
Line 207: Line 206:
 
</figure>
 
</figure>
 
<p><i> Figure 3 : Bioluminescence intensity expressed in RLU of LB and LB + <i>E.coli </i> cells. Mann whitney statistical test was performed (ns: non significant).</i></p>
 
<p><i> Figure 3 : Bioluminescence intensity expressed in RLU of LB and LB + <i>E.coli </i> cells. Mann whitney statistical test was performed (ns: non significant).</i></p>
 
+
<br/>
  
 
<b><font color = "D32C50"> Little leakage in Gaussia luciferase expression</font> </b>
 
<b><font color = "D32C50"> Little leakage in Gaussia luciferase expression</font> </b>
Line 285: Line 284:
 
Therefore, it is essential to realize our bioluminescence test at a precise time after sampling. As we want to detect environmental toluene concentration (less than 20ng/L), it is to be suitable to wait 5h30 before proceeding to the bioluminescence test.
 
Therefore, it is essential to realize our bioluminescence test at a precise time after sampling. As we want to detect environmental toluene concentration (less than 20ng/L), it is to be suitable to wait 5h30 before proceeding to the bioluminescence test.
 
</p>
 
</p>
 
+
<br/>
 
<b><font color = "D32C50"> Investigation of detectable concentration 5h30 after toluene addition to the cells medium</font> </b>
 
<b><font color = "D32C50"> Investigation of detectable concentration 5h30 after toluene addition to the cells medium</font> </b>
  
Line 380: Line 379:
 
</p>
 
</p>
  
 
+
<br/>
 
<b><font color = "D32C50"> Quantification of environmentally relevant toluene concentration </font> </b>
 
<b><font color = "D32C50"> Quantification of environmentally relevant toluene concentration </font> </b>
  

Revision as of 23:00, 17 October 2016

Toluene evaporation test

Protocol

The toluene is known to be a volatile compound. This is why we decided to determine its rate of evaporation before proceeding to any subsequent manipulation with toluene. This will determine the care taken when handling it as well as the time the stock solution will be kept.
1mL of pure toluene (867g/L, 244511 Sigma-Aldrich) was added in a 1.5mL Eppendorf tube. The tube was left open under a chemical hood and its weight was calculate every 30 minutes.

Results

Time

Weight

1h

Weight

1h30

Weight

2h

Weight

2h30

Weight

As shown in the table above, after 6 hours the weight decrease ……. compared to the starting weight.
With this result, we can next test the lethality of E.Coli DH5α when exposed to several toluene concentrations. Moreover, those results ensure that the toluene will not evaporate from the liquid medium during an incubation time of 6 hours or less.
The stock solution of toluene will be prepare again for each replicates.

Survival test to toluene

Protocol and tested concentrations

The protocol 12 (available here ) was used to asses cell survival in presence of toluene. We tested a large range of concentrations (from 5ng/L to 5mg/L) to evaluate the impact of toluene on the E.coli DH5α cell growth. 5ng/L is a concentration closed to environmental toluene concentration.
An overnight culture of bacteria tranformed with our biosensor was realize. 300µL of this overnight culture was inoculated into 150mL of LB containing chloramphenicol at 25ng/mL. This culture was homogenize and separate into several falcon tubes. Tolune was then added to reach its desired concentration. Three replicates of each concentration were done to ensure statistical results.
The OD600 was then checked every hours during 8 hours.

Results

The graph 1 shows the evolution of sample absorbance according to the time and the toluene concentration added in cell culture medium. The curve shows normal growth profile with a lag phase of three hours and then an exponential phase for all samples whether the toluene concentration added in the cell culture medium.
The toluene did not show a significant effect on cell growth at concentration of 5ng/L and 500ng/L. The growth curve shows the same profile than cells grew without toluene. At a concentration of 5mg/L of toluene in the medium, a small effect can be noticed. Four hours after toluene addition, the OD600 of cell grown in 5mg/L of toluene increased slowlier than the OD600 of cell grown without toluene.
According to those results, bioluminescence test were realized with a toluene concentration comprised between 0 and 10 mg/L.




Figure 1 : Evolution of E.coli DH5α grotwh depending on the toluene concentration added in the cell culture medium

Biosensor characterization

Protocol and tested concentrations

We used the protocol 13 (available here )and decided to test several concentration of toluene (0ng/L, 10ng/L, 100ng/L, 10µg/L and 10mg/L).Bioluminescence assays were realized several times after toluene addition (1h, 3h, 4h30 and 5h30).
Bacteria transformed with our biosensor used in each assays come from the same culture (OD = 0.1). This culture was well mixed and divided in 50 mL falcon. Toluene was then added in each Falcon.
All the test were realized in triplicates.
Bioluminescence assay were realized quickly after substrate addition and the bioluminescence intensity was measured using Mithras² LB 943 Monochromator Multimode Reader.This machine was kindly lend by Berthold company for 3 days in order to let us realized the bioluminescence measurement.
Sample's ODs were also measured.
Several negative control were realized :

  • Measurement of LB bioluminescence intensity to determine the background noise

  • Measurement of LB + toluene bioluminescence intensity (effect of toluene on the bioluminescent intensity)

  • Measurement the bioluminescence intensity of bacteria transformed with a genetic construction that do not contain the gaussia luciferase gene (Pr-XylR).

  • A positive control using Pr-Gluc (BBG1) to test our substrate efficiency and the luminometer parameters could have been made during the three days of measurement. However, this biobrick was created afterwards. This biobrick will serve as a future control for all bioluminescence measurement in iGEM project to ensure the substrate efficiency.

    Preliminary considerations


    Toluene does not have auto-bioluminescence

    We determine the effect of adding toluene to cell culture medium on bioluminescence intensity. As shown on the graph below the bioluminescence intensity of the LB + toluene at 10 mg/L (47.71 RLU) do not significantly differ from the bioluminescence intensity of the LB (48.93 RLU). The little bioluminescence found was due to the substrate added in our sample.
    Therefore, toluene addition in our sample will not impact their bioluminescence intensity.

    LB without toluene

    LB with toluene at 10mg/L

    Mean

    48.93 RLU

    47.71 RLU

    Standard deviation (SD)

    6.96

    9.55

    Std. error of mean(SEM)

    1.87

    2.55

    Figure 2 : Bioluminescence intensity expressed in RLU of LB and LB with toluene at 10mg/L. Mann whitney statistical test was performed to asses the effect of toluene on LB auto-bioluminescence (ns: non significant).


    Bacteria E.coli have little auto-bioluminescence

    Bacteria transformed with a genetic construction that does not contain Gaussia luciferase gene were used in this study. The auto-bioluminescence of E.coli cells was assessed by comparate E.coli bacteria bioluminescence intensity to LB bioluminescence intensity. As shown on the figure 3, the bioluminescence intensity of E.coli cells (53.14 RLU) was a little superior to LB bioluminescence intensity (48.93 RLU) but not significantly superior. E.coli cells have little auto-bioluminescence. However, this bioluminescence in greatly inferior to the one produce by our biosensor in presence of pollutant (results presented after)

    LB without toluene

    BB12 without toluene

    Mean

    48.93 RLU

    53.14 RLU

    Standard deviation (SD)

    6.96

    11.34

    Std. error of mean(SEM)

    1.86

    3.03

    Figure 3 : Bioluminescence intensity expressed in RLU of LB and LB + E.coli cells. Mann whitney statistical test was performed (ns: non significant).


    Little leakage in Gaussia luciferase expression

    We investigate the inductility of the Pu promoter to ensure that the gaussia luciferase is not constitutively produce in our biosensor. To do so we compared the bioluminescence intensity of bacteria containing our biosensor to the bioluminescence intensity of bacteria transformed with a genetic construction that do not contain the Gaussia luciferase gene (BB12 : Pr-RBS-XylR).
    The obtained results (figure 4) indicate that the gaussia luciferase gene is not produce in a constitutive manner in the cells. The bioluminescence intensity of our biosensor without toluene injection (158.86 RLU) is a little higher than the bioluminescence intensity of cells transformed with BB12 (53.14 RLU). However this bioluminescence intensity is significantly lower than the bioluminescence intensity of the cells transformed with our biosensor in presence of toluene (results presented in the next section)

    BB12 without toluene

    BB123 without toluene

    Mean

    53.14 RLU

    158.86 RLU

    Standard deviation (SD)

    11.34

    20.08

    Std. error of mean(SEM)

    3.03

    3.10

    Figure 4 : Bioluminescence intensity expressed in RLU of E.coli cells transformed with a construction genetic that contain (BB123) or do not contain (BB12) the gaussia gene. A little leakage of the gaussia gene can be seen as the bioluminescence intensity of the sample that contain bacteria transformed with our biosensor is significantly superior to the one that contain bacteria transformed with Pr-RBS-XylR. Mann whitney statistical test was performed (*** : extremely significant).

    Data processing

    Due to the little LB background noise and leakage in gaussia luciferase synthesis, obtain bioluminescence intensity results were treated as followed. The background noise (LB+toluene) was subtracted to each sample’s bioluminescence intensity. Those latest were then expressed depending on the negative control (bacteria transformed with our biosensor in a medium without toluene, C0).

    Results

    Investigation of the best measurement time

    It was first necessary to determine when, after toluene injection, bioluminescence results were the most relevant. To do so, we determine the bioluminescence intensity of our sample (bacteria transformed with our biosensor within LB medium containing different toluene concentration) several times after toluene addition.
    The bioluminescence intensity of the negative control was also determine at each time after toluene addition and bioluminescent results for each assay were normalized on the corresponding negative control bioluminescence intensity. This normalization was necessary as we are dealing with several incubation time. This enable us to handle the bacteria OD increase within our samples and ensure that an increase in sample’s bioluminescence intensity is not correlated with an increase in cells concentration.
    The graphs presented below represent the bioluminescence intensity of the sample depending on the time after a toluene addition for a fix concentration of toluene injected.

    Figure 5 : Evolution of bioluminescence intensity at different times after toluene addition (10ng/L). The bioluminescence intensity of each sample is normalized on the bioluminescence intensity of the corresponding negative control. Mann whitney statistical test was performed (ns : non significant, * : significant, ** : very significant, *** : extremely significant)

    Figure 6 : Evolution of bioluminescence intensity at different times after toluene addition (100ng/L). The bioluminescence intensity of each sample is normalized on the bioluminescence intensity of the corresponding negative control. Mann whitney statistical test was performed (ns : non significant, * : significant, ** : very significant, *** : extremely significant)

    Figure 7 : Evolution of bioluminescence intensity at different times after toluene addition (10µg/L). The bioluminescence intensity of each sample is normalized on the bioluminescence intensity of the corresponding negative control. Mann whitney statistical test was performed (ns : non significant, * : significant, ** : very significant, *** : extremely significant)

    Figure 8 : Evolution of bioluminescence intensity at different times after toluene addition (10mg/L). The bioluminescence intensity of each sample is normalized on the bioluminescence intensity of the corresponding negative control. Mann whitney statistical test was performed (ns : non significant, * : significant, ** : very significant, *** : extremely significant)

    The bioluminescence intensity of all our samples was compared to the bioluminescence intensity of the negative control for each time after toluene injection. Mann Whitney statistics test were realized to determine whether the bioluminescence intensity of the sample was significantly higher than the bioluminescence intensity of the negative control.
    On the graphics we can notice that the bioluminescence intensity increase as the time after toluene injection increase. However, for the highest concentration (10 mg/L), a decrease in the bioluminescence intensity can be notice 5h30 after toluene injection. It is due to the accumulation of gaussia luciferase and the impact of toluene on the cell metabolism and especially protein synthesis (for more information click here ).
    Therefore, it is essential to realize our bioluminescence test at a precise time after sampling. As we want to detect environmental toluene concentration (less than 20ng/L), it is to be suitable to wait 5h30 before proceeding to the bioluminescence test.


    Investigation of detectable concentration 5h30 after toluene addition to the cells medium

    As we determined that it was preferable to wait 5h30 before realizing the bioluminescence assay, we decided to focus on the results obtain for this time after toluene addition in the cells medium. We studied the evolution of the bioluminescence intensity according to the toluene concentration added in the cells medium 5h30 before. Those tests were realize in triplicates.
    First of all, we wanted to ensure that the OD of the different samples is the same 5h30 after bacteria inoculation in presence of toluene. As shown on the graph below, the sample’s ODs are quite similar going from 1.464 to 1.61.

    Figure 9 : Sample's ODs depending on the toluene concentration added 5h30 before

    The bioluminescence intensity of each samples was then determined and shown depending on the toluene concentration. As we are dealing with extremely different toluene concentration, it was preferable to give our results in function of the logarithm of the toluene concentration. The bioluminescence intensity data in RLU for each replicates (R1, R2, R3) are given in the table below and represented on the graph 10.

    Toluene concentration

    Logarithm of toluene concentration

    Mean - R1 (RLU)

    SD - R1

    Mean - R2 (RLU)

    SD - R2

    Mean - R3 (RLU)

    SD - R3

    0 ng/L

    0

    180.2

    16.0

    146.5

    23.4

    167.9

    11.8

    10 ng/L

    1

    1007.3

    210.2

    337.7

    39.3

    1041.9

    139.4

    100 ng/L

    2

    754.4

    150.4

    762.4

    77.9

    1823.1

    243.1

    10 µg/L

    4

    1110.4

    150.0

    1373.8

    162.4

    2073.7

    202.9

    10 mg/L

    7

    882.8

    131.6

    2485.4

    259.5

    1247.2

    151.4

    Figure 10 : Evolution of bioluminescence intensity for each replicate depending on the logarithm of the toluene concentration injected 5h30 before

    As shown on the graph, the obtained data differ from one replicates to another due to difference in the metabolism which is normal when working with living organism. However the curve profile stay is the same : the bioluminescence intensity of the sample increases until a toluene concentration of 10 µg/, then it reaches a plateau for two replicates and continues to increase for the other replicate.
    Those results were pooled in order to draw a standard curve and being able to predict toluene concentration in a sample according to the bioluminescence intensity.


    Quantification of environmentally relevant toluene concentration

    The figure 11 shows the evolution of the bioluminescence intensity depending on the logarithm of toluene concentration. For a toluene concentration inferior to 10 µg/L (10,000 ng/L : log(4)) the curve increases steadily, then the curve reach a plateau. This can be due to gaussia accumulation in the cells.
    We were able to detect environmentally relevant toluene concentration and as the standard curve is linear for a toluene concentration inferior to 10µg/L, we are able to quantify the toluene concentration of a given sample.

    0 ng/L

    10 ng/L

    100 ng/L

    10 µg/L

    10 mg/L

    Mean (RLU)

    164,84

    795,63

    1139,88

    1519,28

    1538,45

    Standard deviation

    17,62

    129,73

    146,68

    171,75

    180,84

    Induction percentage

    383%

    592%

    822%

    833%

    Figure 11 : Evolution of bioluminescence intensity for pooled of the replicate depending on the logarithm of the toluene concentration injected 5h30 before. Correlation between toluene concentration in the cell culture medium and the bioluminescence intensity

    Comparison with existing methods

    Perspectives and improvement