Difference between revisions of "Team:HokkaidoU Japan/Aggregation"

Line 15: Line 15:
 
<br>
 
<br>
  
<table style="border-style: none">
+
<table style="border-style: none; width:1px; margin-left:auto; margin-right:auto;">
 
<tr align="center">  
 
<tr align="center">  
 
<td style="border-style: none;">  
 
<td style="border-style: none;">  
Line 43: Line 43:
 
</span>
 
</span>
 
<br>
 
<br>
<table style="border-style: none">
+
<table style="border-style: none; width:1px; margin-left:auto; margin-right:auto;">
 
<tr align="center">  
 
<tr align="center">  
 
<td style="border-style: none;">  
 
<td style="border-style: none;">  

Revision as of 15:51, 19 October 2016

Team:HokkaidoU Japan - 2016.igem.org

 

Team:HokkaidoU Japan

\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\


overview

When you harvest E. coli on your laboratory, is there the way to aggregate E. coli efficiently with the SAP? We try to suggest the expression of the SAP on E. coli flagellum. Perhaps, a new method for the E. coli aggregation, except for Ag43 which has been adopted by some iGEM teams[1][2], may be found.

aggregation
Fig. 1. Image of aggregation using SAP
E. coli are aggregated by the binding through SAP. SAP is expressed on the fllagerum.





design

FliC is an important domain which forms the filament (Fig. 2)[3]. It is known that any protein can be inserted into its domain without losing the function of the flagellar. So we think that the aggregation of E. coli because of the bindings between the flagellar is likely to happen by inserting SAP, for example, RADA16-I and P11-4. Since it has been reported that the overexpression of the Ag43 decreases the survival rate of E. coli, we have to search for an alternative method for the aggregation of E. coli.
Therefore we propose that inserting the SAP has an advantage of improving the efficiency of the consecutive chemical reactions when E. coli which have different functions approach each other.

filament
Fig. 2. Image of E. coli's filament
Any protein can be inserted into the FliC.





conclusion

There may still be room for improvement for the financial aspect or the efficiency regarding the way to harvest E. coli in the laboratory. And a more simple method would be much more desirable without any expensive biological device. At last we wish that more research will be conducted of the difference between the efficiency of the aggregation of E. coli with the biological tools, for example Ag43, RADA16-I, and P11-4. And we also desire for the possibility of the aggregation of E. coli with the SAP we suggest.


reference

[1] HokkaidoU Japan 2012
[2] Aberdeen Scotland 2014
[3] Kuwajima, G. 1988. Construction of a minimum-size functional ?agellin of Escherichia coli. J. Bacteriol. 170:3305?3309.