Line 47: | Line 47: | ||
<div class="col-lg-12"> | <div class="col-lg-12"> | ||
<h3 id="APrinciple">(1) Principles and Methods</h3> | <h3 id="APrinciple">(1) Principles and Methods</h3> | ||
− | + | ||
− | The biofilm, whose subunit was CsgA engineered with HisTag on N-termial and SpyCachter-HisTag on C-terminal, was grown on microspheres, 25 micrometers in diameter for 48 hours. NR’s (7.72*10^-9 M) were then added and given 30 min to bind to the HisTag on CsgA subunit. (The engineered SpyCatcher was used for future pure hydrogenase binding.) The solution was centrifuged and the sediments contained biofilm beads covered with NR. This sediment was resuspended in PBS and was added to the reaction solution consisting of <em>E. coli</em> with engineered hydrogenase (wet weight 100ug) resuspended in PBS, 150Mm NaCl, 100mM VitaminC, and mediator solution (5mM Paraquat dichloride, for mediating the electrons across the cell membrane). The whole solution including bacteria is adjusted to pH=4 by 100mM Tris-HCl(pH=7.0), given that the pH of 4 was reported to be an optimal environment.<span style=”font-size:12px”> </span> Prior to the assay, the <em>E. coli</em> was induced with IPTG overnight at room temperature. <h3 id="AInstrument">(2) Instrument</h3> | + | The biofilm, whose subunit was CsgA engineered with HisTag on N-termial and SpyCachter-HisTag on C-terminal, was grown on microspheres, 25 micrometers in diameter for 48 hours. NR’s (7.72*10^-9 M) were then added and given 30 min to bind to the HisTag on CsgA subunit. (The engineered SpyCatcher was used for future pure hydrogenase binding.) The solution was centrifuged and the sediments contained biofilm beads covered with NR. This sediment was resuspended in PBS and was added to the reaction solution consisting of <em>E. coli</em> with engineered hydrogenase (wet weight 100ug) resuspended in PBS, 150Mm NaCl, 100mM VitaminC, and mediator solution (5mM Paraquat dichloride, for mediating the electrons across the cell membrane). The whole solution including bacteria is adjusted to pH=4 by 100mM Tris-HCl(pH=7.0), given that the pH of 4 was reported to be an optimal environment.<span style=”font-size:12px”> </span> Prior to the assay, the <em>E. coli</em> was induced with IPTG overnight at room temperature. |
+ | |||
+ | In the activity assay of the hydrogenase in producing hydrogen, the system goes through three periods of “light-on and light-off”. The result (see below) shows the stability of the system and the reversible catalytic activity of the hydrogenase of the reaction, 2H+ + 2e- ⇿ H2 .<p></p><h3 id="AInstrument">(2) Instrument</h3> | ||
<center><img src="https://static.igem.org/mediawiki/2016/e/ef/Hydrogenapp.png"></center> | <center><img src="https://static.igem.org/mediawiki/2016/e/ef/Hydrogenapp.png"></center> |
Revision as of 02:51, 19 October 2016