Buzzers, balanced amatures and speakers were tried as sonic stimulators. Only buzzers induced obvious cell response in high frequency conditions (15KHz and 20KHz). A buzzer was attached to the bottom of a cell dish. When the buzzer was working, cells around the buzzer boundary was observed under microscope. Strong fluorescence intensity increased immediately after the buzzer was started.
 
Buzzers, balanced amatures and speakers were tried as sonic stimulators. Only buzzers induced obvious cell response in high frequency conditions (15KHz and 20KHz). A buzzer was attached to the bottom of a cell dish. When the buzzer was working, cells around the buzzer boundary was observed under microscope. Strong fluorescence intensity increased immediately after the buzzer was started.
 
Cell fluorescence intensity increased greatly when stimulated by 15K and 20KHz sound. While no obvious fluorescence intensity change when GECO cells (without MS channel) were stimulated(Fig. ).
 
Cell fluorescence intensity increased greatly when stimulated by 15K and 20KHz sound. While no obvious fluorescence intensity change when GECO cells (without MS channel) were stimulated(Fig. ).
{{SUSTech_Image | filename=T--SUSTech_Shenzhen--POCSrtheteyh.jpg}}{{SUSTech_Image | filename=T--SUSTech_Shenzhen--POCStrwgtvbwr.jpg}}
+
{{SUSTech_Image | filename=T--SUSTech_Shenzhen--POCSrtheteyh.jpg | width=400px}}{{SUSTech_Image | filename=T--SUSTech_Shenzhen--POCStrwgtvbwr.jpg | width=400px}}
{{SUSTech_Image | filename=T--SUSTech_Shenzhen--fgbgfbhetygh.png}}
+
{{SUSTech_Image | filename=T--SUSTech_Shenzhen--fgbgfbhetygh.png | width=4\1000px}}
  
 
== Ultrasonic Stimulation ==
 
== Ultrasonic Stimulation ==
  
 
Ultrasonic transducers can transform electric energy into ultrasonic radiant energy. There were four kinds of ultrasonic transducer tried. Pressure fields of 108KHz and 1.1MHz transducers were simulated for different power and distance. The pressure field distribution changes smoothly, while the pressure distribution was quite chaos in condition of 1.1MHz. Only strong cell response was observed in condition of 108KHz stimulation as shown in Fig. No obvious cell response was observed for 1.1MHz stimulation.
 
Ultrasonic transducers can transform electric energy into ultrasonic radiant energy. There were four kinds of ultrasonic transducer tried. Pressure fields of 108KHz and 1.1MHz transducers were simulated for different power and distance. The pressure field distribution changes smoothly, while the pressure distribution was quite chaos in condition of 1.1MHz. Only strong cell response was observed in condition of 108KHz stimulation as shown in Fig. No obvious cell response was observed for 1.1MHz stimulation.
{{SUSTech_Image | filename=T--SUSTech_Shenzhen--POCStrhteyhj.jpg}}{{SUSTech_Image | filename=T--SUSTech_Shenzhen--POCSfbetyhtey.png}}
+
{{SUSTech_Image | filename=T--SUSTech_Shenzhen--POCStrhteyhj.jpg | width=400px}}{{SUSTech_Image | filename=T--SUSTech_Shenzhen--POCSfbetyhtey.png | width=400px}}
  
 
In experiment, 108KHz 4.1W ultrasonic device induced a strong cell response as is shown in the following. However, no cell response was observed when cells were stimulated by 1.1MHz transducer with the same power(Fig. ).
 
In experiment, 108KHz 4.1W ultrasonic device induced a strong cell response as is shown in the following. However, no cell response was observed when cells were stimulated by 1.1MHz transducer with the same power(Fig. ).
{{SUSTech_Image | filename=T--SUSTech_Shenzhen--POCSrwgttehtey.jpg}}
+
{{SUSTech_Image | filename=T--SUSTech_Shenzhen--POCSrwgttehtey.jpg | width=1000px}}
  
 
== Long-term Stimulation ==
 
== Long-term Stimulation ==

Revision as of 07:37, 19 October 2016

Team SUSTC-Shenzhen

Proof of Concept

Project

Overview

To implement audio-genetics, we chose two (Piezo1 and TRPC5) from hundreds of mechanosensitive(MS) channels that are relevant to sensing mechanical stress such as sound wave, because they are more sensitive to mechanical stress and more selectively permeable to calcium ion compared with others. Additionally, we used calcium indicator (R-GECO) to quantitatively examine the sensibility of Piezo1 and TRPC5 with the help of microfluidics and hypo-osmolality, the former one was to exert shear force on our transgenic CHO-K1 cell's membrane, the latter one was to exert tension on cell's membrane.

We also examined the intracellular calcium response to sound wave with different combination of frequency and intensity in advance, then we quantitatively analyzed the regulation ability of audio-genetics in long term by using special promoter (pNFAT) with its downstream GFP gene.

Finally, to ensure a required sensitivity to mechanical stress and select a series of audio respondent channels, we used protein engineering by directed evolution to get mutated sTRPC5 (super TRPC5) with high sensitivity to mechanical stress. All in all, our project is well organized. Each procedure is indispensable. The whole project can strongly prove the possibility of using sound wave energy as the extracellular input signal to induce intracellular downstream signal.

1. Testing the PiggyBac System

In order to quantitatively test the function of PiggyBac system, we made two groups of transfection using Lipofectamine® 3000. One was a group of CHO-K1 cells transfected with R-GECO, and the other group was the cells transfected with R-GECO and PiggyBac.

T--SUSTech Shenzhen--PiggyBac-POC.png
Fig.1 Result of Quantitatively Test the Function of PiggyBac System all pictures was capture by Nikon microscope (Nikon TS100) with 20 magnification times on the second day after transfection. a) Bright field image of the cells only transfected with R-GECO. b) Fluorescence image of the cell only transfected with R-GECO. c) Bright field image of the cells transfected with R-GECO and PiggyBac. d) Fluorescence image of the cell only transfected with R-GECO and PiggyBac.

Comparing the fluorescence image of the cell transfected with R-GECO (Fig. 1B) with R-GECO + PiggyBac (Fig. 1D) on the second day after transfection, we can observe that the group with PiggyBac has more fluorescent cells. It proves that PiggyBac transposon system can help the insertion of R-GECO gene into CHO-K1 genomes.

2. Examination of R-GECO Function

To quantitatively test the function of R-GECO, two experiments, potassium chloride (KCl) induced calcium influx and ionomycin induced calcium influx, were conducted under the live cell imaging.

T--SUSTech Shenzhen--R-GECO-POC.png
Fig.2 KCl Induced Ca2+ Influx Result KCl was added at 40s. Fluorescence intensity over time is shown as signal per pixel (the initial intensity has been normalized to 0). The data above are shown as mean ± SEM, n = 5 for 0 mM control, 12.5 mM, 50 mM, 200 mM.

Calcium influx due to depolarization of cell membrane was induced by different concentration of KCl. Different volume of KCl was added by drops into cell culture wells to reach the different final concentrations of KCl (0mM control, 12.5mM, 50mM, 200mM, respectively) at 40 second.

There was no distinct fluorescent increasing at 12.5mM KCl comparing with the control group. The cells under 50mM and 200mM KCl conditions both emitted high fluorescence, and the fluorescence of cells at 200mM was higher than cell at 50mM along with oscillation. It was proved quantitatively that R-GECO could be excited by KCl induced calcium influx.

T--SUSTech Shenzhen--GECO-Ionomycin.png
{{{caption}}}

A B

Fig. Ionomycin induced Ca2+ influx result. Fluorescence intensity over time is shown as signal per pixel (the initial intensity has been normalized to 0). The data are shown as mean ± SEM, n = 5 for control, 10 μM ionomycin.

R-GECO’s response to calcium influx was also tested by ionomycin which was added at 20s. After adding ionomycin (10μM final concentration), the increase of R-GECO fluorescence was distinct. Because the ionomycin was dropped beside the observed region of cells, the direction of fluorescence gradient (shown in the movie) was in accordance with the direction of ionomycin diffusion.

3. Measure Piezo1 and TRPC5 Sensitivity

We designed two experiments to quantitatively examine the sensibility of Piezo1 and TRPC5. Microfluidics and hypoosmolality were employed to exert shear force and tension on our transgenic CHO-K1 cell's membrane separately.

Microfluidics

Fig.1 a Schematic structure of microfluidics channel

T--SUSTech Shenzhen--Microfluidics-POC.png
Fig. Cells in microfluidics chips 24hrs after seeding (待换图,用live cell 拍的)

CHO-K1 cells were cultured adherent on the bottom glass of PDMS tunnel. Stable and flexible force field was formed surrounding cell, directly controlled by the pumped-inflow rate.

See the design of microfluidics chip and the simulation of force field at https://2016.igem.org/Team:SUSTech_Shenzhen/Model


1000px
Fig. Fluorescent intensity (待补图)

CHO-K1 cell suspension was injected into gelatin treated microfluidics chips and incubated at 37°C, 5% CO2 incubator for 24 hours. Then the culture medium was injected into the chip channels (with the inflow rate of 25μL/min, 50μL/min and100μL/min controlled by micro syringe pump). The pump of culture medium started at t=10s. Cells’ response towards different shear force was measured by R-GECO fluorescence intensity under live cell imaging. (waiting result)

discussion! (modeling)

Hypoosmolarity

T--SUSTech Shenzhen--hypoosmo-A.png
{{{caption}}}

A

T--SUSTech Shenzhen--hypoosmo-B.png
{{{caption}}}

B

Fig. Osmotic pressure test result. Fluorescence intensity over time is shown as signal per pixel (the initial intensity has been normalized to 0). The data are shown as mean ± SEM, n = 5 for 3 groups of 100%, 90%, 80%, 70%, 60% or 50%.

Calcium influx was indicated by R-GECO fluorescence intensity. Culture medium was replaced by HHBSS before using live cell imaging. Three groups of cells were seeded into 18 wells: 6 wells of R-GECO, 6 wells of Piezo1 (without doxycycline inducement) and 6 wells of Piezo1 (with doxycycline inducement). Distilled water (added with CaCl2) was added into wells to make concentration of HHBSS into 100%, 90%, 80%, 70%, 60% or 50% for 3 groups.

4. Analyze the regulatory ability of audiogenetics

We designed both ultrasonic and audible sonic simulation hardware to quantitatively stimulate cells.

Audible Sonic stimulation

Buzzers, balanced amatures and speakers were tried as sonic stimulators. Only buzzers induced obvious cell response in high frequency conditions (15KHz and 20KHz). A buzzer was attached to the bottom of a cell dish. When the buzzer was working, cells around the buzzer boundary was observed under microscope. Strong fluorescence intensity increased immediately after the buzzer was started. Cell fluorescence intensity increased greatly when stimulated by 15K and 20KHz sound. While no obvious fluorescence intensity change when GECO cells (without MS channel) were stimulated(Fig. ).

T--SUSTech Shenzhen--POCSrtheteyh.jpg
{{{caption}}}
T--SUSTech Shenzhen--POCStrwgtvbwr.jpg
{{{caption}}}
4\1000px
{{{caption}}}

Ultrasonic Stimulation

Ultrasonic transducers can transform electric energy into ultrasonic radiant energy. There were four kinds of ultrasonic transducer tried. Pressure fields of 108KHz and 1.1MHz transducers were simulated for different power and distance. The pressure field distribution changes smoothly, while the pressure distribution was quite chaos in condition of 1.1MHz. Only strong cell response was observed in condition of 108KHz stimulation as shown in Fig. No obvious cell response was observed for 1.1MHz stimulation.

T--SUSTech Shenzhen--POCStrhteyhj.jpg
{{{caption}}}
T--SUSTech Shenzhen--POCSfbetyhtey.png
{{{caption}}}

In experiment, 108KHz 4.1W ultrasonic device induced a strong cell response as is shown in the following. However, no cell response was observed when cells were stimulated by 1.1MHz transducer with the same power(Fig. ).

T--SUSTech Shenzhen--POCSrwgttehtey.jpg
{{{caption}}}

Long-term Stimulation

NFAT part can start gene expression when triggered by influx. The NFAT+Piezo1 cell expresses GFP when its MS channels open inducing a Ca2+ influx. And here we used two kinds of MS channels: PIEZO1 and TRPC5. We are currently doing 20h, 108KHz, 4.1W ultrasonic stimulation experiment on Piezo1+NFAT cells and Piezo1+NFAT cells. Our programmable 108KHz ultrasonic device is now used to stimulate cells in a certain mode (5s on, 15s off).

5. Select through Cre-loxp system

Cre-loxp system played an important role in directed evolution, because we needed to screen a single cell colony only with one loxp site in the genome of each CHO-K1 cell for single copy insert of mutated TRPC5. Here we tested the function of cre-loxp system by making 3 different groups of transfection in the cells that already inserted with loxp gene on genomes using Lipofectamine® 3000.

T--SUSTech Shenzhen--cre-loxp-poc.png
Fig. Result of the test of Cre-loxp system. All pictures was captured by Nikon microscope (Nikon TS100) on the fifth day after transfection, also the third day after antibiotics (neomycin) screening. a) Bright field image of the cells transfected with neomycin-loxp gene. b) Bright field image of the cells transfected with Cre recombinase and neomycin-loxp gene (3:3). c) Bright field image of the cells transfected with Cre recombinase and neomycin-loxp gene (1:3).

Few cells survives (Fig1. a) after antibiotics screening without transfecting Cre recombinase gene, which means that there is a small possibility that loxp gene can insert into genomes by interior transposase in cells. To find out the optimal ratio of Cre recombinase gene to Neomycin-loxp gene in the process of transfection, we compared two different ratio, 3:3 (Fig1. b) and 1:3 (Fig1. c), with equal amount of Neomycin-loxp gene but different amount of Cre recombinase gene.

From observation, we know that excess Cre recombinase is not appropriate in transfection process. The most possible reason is that surplus Cre recombinase is harmful for cells, so they may random cut and recombine genes in cell’s genome. Thus, we finally chose 1:3 as the ratio of Cre recombinase gene to Neomycin-loxp gene in transfection.

6. Mutagenesis Library of TRPC5

Mutation frequency calibration

1. Define ideal mutation frequency

Mutation frequency is the product of DNA polymerase error rate and number of duplications, it depends on initial target amount and fold amplification. Mutation frequencies of 1~4 amino acid changes (2~7 nucleotide changes) per gene are commonly employed.

We have mutated the Ankyrin repeats (734bp length) of TRPC5 by employ 500ng initial tartget and 32 cycle amplification according to the protocol of GeneMorph II Random Mutagenesis Kit (Agilent Technologies,Catalog #200550). 


2. Calibration of mutation frequency by sequencing

To calibrate the mutation frequency in experimental condition, we sequenced 20 mutated TRPC5 samples in the region of ankyrin repeats. The table below shows the correspondence between mutation(s) and sequenced sample numbers.

Mutation(s) 1 2 0
Sample Numbers 4 1 14

Table 1 Practical mutations and sample numbers

5 samples have been detected mutation(s). However, the transformation result showed that the digestion might be incomplete (Table 2). Still, the data could offer us some information. Basically, the practical mutation frequency with initial target amount of 500ng was similar with the theoretical mutation frequency.

Colonies Control
10688 113

Table 2. Transformation result of mutated TRPC5 ligation product vs control

To construct a large-scale mutation library with different mutation frequencies in the specific region, we also did error-prone PCR with different initial target amounts to get TRPC5 mutants with low, medium and high mutation rate.

Library construction

3. Calculate competent cell efficiency from experimental result

(1). Formula: \frac{\text{Colonies}}{\text{ng of DNA plated}}\times 1000ng/\mu g

(2). Calculation: 237 / 0.02 x 1000=1.185x107 cfu/μg

(3). Actual meaning: 20pg, 5640bp TRPC5 plasmid → 3.457x106 copies

3.457x106 / 237=14586, which means 1 of 14586 plasmids would actually grow on the plate.

4. Compare three methods for mutation library construction

Method Colonies Control
R. E. D and Ligation 1772 330
Whole Plasmid Mutagenesis 191 0
Gibson Assembly 38 7

Table 5. Transformation Results of Three Methods for Mutation Library Construction. All groups were transformed with 5μl products after all experiment procedure with 100ul competent cell. Restriction Enzyme Digestion and Ligation method and Gibson assembly method used the same mole of TRPC5 backbone. Transformation operations were all the same.

From the table, we can know Restriction Enzyme Digestion and Ligation method is the most efficient way of constructing library.

(1). 62ng, 4906bp plasmid → 1.232x1010 copies

(2). Efficiency= \frac{(1772-330)\times 20 \div 5}{1.232 \times 10^10 \times \frac{1}{14586}}\times 100\% = 0.68\%

We needed to consider their effect on CHO-k1 cell if being directly transfected without transformation and plasmid construction. Since the ligation efficiency was 0.68%, we did an experiment comparing the survival rate of CHO-k1 cells after being transfected with linear DNA and circular DNA. After antibiotic screening, we luckily found that the former one were almost dead, while the latter one were good. Thus we could directly transfect the ligation products into cell without transformation, preventing the mutation library from decreasing.

See Details

7. Screening cells for Audio-genetics test

1. Transfect the cells with loxp gene, pNFAT+GFP gene, R-GECO gene (calcium indicator) by PiggyBac system and sort them into single colonies by FACS (BD FACSAria)

T--SUSTech Shenzhen--E9381DE8-3AF7-432D-97AD-C712CEC4491E.png
Fig 1. the R-GECO and GFP fluorescence of wild type cells and cells transfecd with loxp gene, pNFAT+GFP gene, R-GECO gene

The data was collected in the process of sorting by FACS, total cells count is 10000. Cells transfected with R-GECO gene will continually express R-GECO, because CAG promoter is a constitutive promoter. Thus, most cells have red fluorescence (Fig1. b) compare with wild type control (Fig1. a). Cells transfected with pNFAT+GFP should not express GFP because promoter NFAT need to be activated by calcium signal indirectly. However, most cells still can express GFP (Fig.1 d) compare with wild type control (Fig.1 c), which mean there is some leak expression of promoter NFAT. 2. Select the single cell colony only with one copy number of loxp by qPCR
To evaluate the efficiency of each mutated channels, single cell colony with only one copy number is required when testing, so we designed the following experiments to achieve it. 

 2.1 Primer design and primer efficiency test

The real-time PCR primers (Forward: TTGTCAAGACCGACCTGTCC, Reverse: TTCAGTGACAACGTCGAGCA) were designed by Primer-BLAST, a tool for finding specific primers, followed by BLAST specificity check. Firstly, we selected an appropriate annealing temperature to avoid unnecessary amplification as well as improving primer efficiency by normal PCR test in wild type CHO-K1 genomes, the result indicates that 62℃ may be the most appropriate annealing temperature. In addition, we also confirmed that the amplification product was accurate at 62℃ when the target was cells genome that transfected with neomycin-loxp gene by sequencing the PCR product.

Real-time PCR ( here we used TaKaRa-SYBR Premix Ex Taq II(Tli RNaseH Plus) ran in the ABI StepOne Plus qPCR instrument) can be used to calculate the primer efficiency of PCR amplification via Equation 1. In which Xn = PCR product quantity after n cycles, X0 = initial copy number, E = amplification efficiency, n = cycle number.

Xn=x0 \times (1+E)^n

Equation 1

The efficiency of the primer is 104% by calculating (Within the usual margin of error, which is 90%~110%). Also, the melt curve has only one peak, which means the designed primer is quite specific to the transfected CHO-K1 cell’s genomic DNA.


2.2 Select the cell colony with single copy number

In each qPCR screening experiment, we made a standard curve by employing a series of 5-fold dilution gradient Neomycin-loxp gene with known mole amount. Therefore, we could quantitatively examined the copy number of neomycin-loxp gene in single colony genomes by fitting the sample Ct data in the standard amplification plot. Standard curve was made by using the following data.

Relative Quantity log(Relative Quantity) Ct
1 0 15.01047802
0.2 -0.698970004 16.94664574
0.04 -1.397940009 19.24198341
0.00032 -3.494850022 25.79216194
-4.193820026 27.9509449

Table 10. Log(Relative Quantity) vs. Ct

Figure 15 Fig. 15 Fitted Standard Curve

(within the usual margins of error, which is 90%~110%)


Fig16 Figure 16. Melt Curve of Neomycin-loxp Transfected CHO-K1 Cell’s gDNA

Copy Number

Mass/ng Ct Relative Quantity 10^-3 fmole Copy Number
78.8075 23.2236 0.002110101 0.0531425 4.054
40.7625 24.1791 0.001040142 0.0274875 3.863
19.0225 25.2316 0.000477161 0.0128275 3.797
Average 3.905

Table 11. Neomycin-loxp Copy Number of CHO-K1 Cell

Relative Quantity =10^\frac{\text{Ct}-14.902}{-3.1101}

Copy Number :

Plasmid used in standard curve: 0.1021 fmol, Relative Quantity=1

fomular (c: copy number)

fig13 Figure 13. Amplification Plot for Standard

fig14 Figure 14. Amplification Plot for Sample

The efficiency of PiggyBac transposon system ranged from 2% for one transposon to 0.5% for five transposons [1]. Consequently, it’s quite possible for us to screen out the cells with single or low copies of Neomycin-loxp.

In practical experiments, we totally test 18 different single colony genomes. The lowest copy number of those selected CHO-K1 cell transfected with Neomycin-loxp is around 4, which was not good enough. The reason may be that the designed primer was not so satisfying. Also, the contamination during real-time PCR was hard to avoid. To get cells with single copy of Neomycin-loxp, we still need to design better primers as well as paying attention to the experiment operations.

3. Transfect the cells with mutated TRPC5 by Cre-loxp system

We are doing these experiments.


use fluorescence activated cell sorting (FACS) to select the cells with high intensity of GFP after long term stimulate

We are doing.




  1. Lu, X. and W. Huang, PiggyBac mediated multiplex gene transfer in mouse embryonic stem cell. PLoS One, 2014. 9(12): p. ell 5072