Difference between revisions of "Team:SUSTech Shenzhen/Model"

Line 53: Line 53:
 
Rainbow beads (SPHEROTM Rainbow Calibration Particles, diameter: 6um) were dissolved in the cell culture medium, which contained the dead cells. A series of pumped flow rate(5ul/min, 15ul/min, and 45ul/min) were applied to generate a steady fluid flow. The exposure time was set to 100ms.
 
Rainbow beads (SPHEROTM Rainbow Calibration Particles, diameter: 6um) were dissolved in the cell culture medium, which contained the dead cells. A series of pumped flow rate(5ul/min, 15ul/min, and 45ul/min) were applied to generate a steady fluid flow. The exposure time was set to 100ms.
  
{{SUSTech_Image | filename=T--SUSTech_Shenzhen--pasted-image-95.tiff|caption=Fig. A typical image of a bead trace in the fast microfluidics channel with a pumped flow rate of 5ul/min.}}
+
{{SUSTech_Image | filename=T--SUSTech_Shenzhen--95.png|caption=Fig. A typical image of a bead trace in the fast microfluidics channel with a pumped flow rate of 5ul/min.}}
  
 
By using MATLAB program, the maximum flow velocities were calculated (13 : 100 : 978).
 
By using MATLAB program, the maximum flow velocities were calculated (13 : 100 : 978).
  
{{SUSTech_Image | filename=T--SUSTech_Shenzhen--2016-10-18 02.55.31.png|caption=Fig. The graph of maximum flow velocities in each channel under the pumped flow rate of 45ul/min.}}
+
{{SUSTech_Image | filename=T--SUSTech_Shenzhen--97.png|caption=Fig. The graph of maximum flow velocities in each channel under the pumped flow rate of 45ul/min.}}
  
 
More details in https://2016.igem.org/Team:SUSTech_Shenzhen/test
 
More details in https://2016.igem.org/Team:SUSTech_Shenzhen/test

Revision as of 19:07, 17 October 2016

Team SUSTC-Shenzhen

Model

Overview

When we were discovering audio-genetics, to find correspondences between our mechanosensitive(MS) channels and different sound wavelengths, we needed the support of modeling and logical result ascription besides constructing a huge mutagenesis library and testing them in vitro continuously, although it is already very hard to do. We designed the experiment based on the discovery of the mechanism of MS channel and applying it on the regulation of downstream gene expression. Modeling has been our guide throughout the project and we finally got the result we initially expected.

In one part, we employed microfluidics to realize the stable force field controlled by fluidic velocity. In-vitro experiments were operated on the designed chips. On the other hand, we used various devices to generate sound field and tested cell response in different conditions.

Finite Element Analysis (FEA) was applied to modeling of the field generated by the microfluidic devices and the acoustic stimulators. Modeling reliability has been tested and confirmed by comparing the calculated result with raw results from the experiments.

Force of Field

To quantitatively measure the response of MS channel on the cell membrane, we designed our experiment manipulated on microfluidic chip. CHO-K1 cells were cultured adherent on the bottom of PDMS tunnel. Stable and flexible force field could be formed surrounding cell, which directly controlled by the pumped-inflow rate. Each time when we applied a constant pumped inflow, cells in 3 different observation tunnel could receive corresponding small, middle, large, 3 level of force magnitude(1: 9: 81). By changing the pumped flow rate, we could measure MS channel response under a series of forces with different magnitude order.

T--SUSTech Shenzhen--rendered-device.png

Mathematical Demonstration

In experiment, when fluid(culture medium x flowed through the tunnel, the shear force was applied on the wall. Seeing the culture medium as a Newtonian flow, it has a constant viscosity μ,0.012dyn·s/cm2[1]. The shear stress that medium generated on the wall is proportional to strain rate. As a result, we could relate the magnitude of stress to the velocity gradient along the transversal surface of each tunnel.

Due to the extremely small scale of microfluidic tunnel (only 0.285mm of width and 0.090mm of height), fluid in it observes the Laminar flow. We could assume there is no turbulence when inflow applied constantly, even at the corners, and the head loss of the pumped inflow could also be ignored. The modeling of flow between 2 parallel plates applies to such stable state, in which the magnitude of shear stress on the bottom is proportional to the maximum velocity( at the longitudinal central line).

As the shear stress is proved proportional to the flow rate in the tunnel, we designed the chip to achieve that each of 3 tunnels in observation area has the same transversal surface but the gradient (81: 9: 1 from up to bottom) flow rate, also the average speed.
The lengths of straight tunnels between AB and AC (LAB, LAC)are 14.3mm and 12.0mm, and the curved tunnels between AB and BC(RAB, RBC) are 108.0 mm and 105.0mm.

T--SUSTech Shenzhen--35011F22BF6BCC10C3DF1F593E43DCF1.jpg
Newtonian fluid flows between two wide, parallel plates Flow driven by pressure difference Parabolic velocity profile given by u = V[1-(y/h)^2] where V is the maximum velocity (along channel centerline y=0) Along bottom wall, y=-h, shear stress \tau=\mu \frac{du}{dy}=\mu(-2V\frac{y}{h^2})=\frac{2\mu V}{h} For a constant flow rate within the tunnel, the average speed remains same \bar V=\frac{Q}{A}=\frac{\int_A udA}{A}=\frac{1}{2}V

T--SUSTech Shenzhen--annotated-device.png

Based on the integral form of the continuity equation for an incompressible fluid, during a given time, the sum of flow volume in each branch is equal to the total volume pumped in the whole chamber. According to the Kirchhoff's law, the accumulation of flow speed at the joint point must be zero. It is easy to get the equation that\begin{matrix} L_{AC}V_1=L_{AB}V_2+R_{AB} V_3 \\ V_2:V_3=R_{AB}:L_{AB} \end{matrix}

Consequently, we could reach the conclusion that the maximum velocity, average flow rate and the shear force on the bottom of each tunnel is at a ratio of 81 : 9 : 1. To verify the modeling result, we made calibration in the real microfluidics chip, and the testing result is very close to designing value (about 75 : 8 : 1 of the maximum velocity ratio in each tunnel) and the simulation result ( 80 : 8 : 1).

Experimental result Analysis

On October 12th, we testify one of our MS channels, Piezo1, under the simulation of shear stress, with R-GECO fluorescent indicating its activation level. (results showed below) 12等今晚结果图放一张和动力学解释(详细解释也另放一页)

Calibration

Rainbow beads (SPHEROTM Rainbow Calibration Particles, diameter: 6um) were dissolved in the cell culture medium, which contained the dead cells. A series of pumped flow rate(5ul/min, 15ul/min, and 45ul/min) were applied to generate a steady fluid flow. The exposure time was set to 100ms.

T--SUSTech Shenzhen--95.png
Fig. A typical image of a bead trace in the fast microfluidics channel with a pumped flow rate of 5ul/min.

By using MATLAB program, the maximum flow velocities were calculated (13 : 100 : 978).

T--SUSTech Shenzhen--97.png
Fig. The graph of maximum flow velocities in each channel under the pumped flow rate of 45ul/min.

More details in https://2016.igem.org/Team:SUSTech_Shenzhen/test

Simulation

To make the analysis of experimental result is convincible, we also made the simulation using the Finite Element Method(FEM) to define that the field in microfluidic channel confirmed to our expectation.

FEM is a method for modeling and simulating physics-based problems. It divides a large problem into smaller elements, these smaller elements will be solved separately and then be assembled backed to the original model. A collection of smaller elements is called a “mesh”, the “mesh” is constructed by numerous elements, the smaller the size of the element is, the finer the “mesh” is, and the more accurate will the result be. We imported the designed pattern file created by SolidWorks® and imported all the material properties.

300px
Fig. Imported Pattern

Under different pumped inflow rate(5μL/min,15μL/min and45μL/min), the velocity magnitude distribution was calculated. The result of maximum velocity and shear force applied on the bottom wall matched with the mathematics perfectly( around 80: 10: 1 in all the conditions, shown in the table below).

300px
Fig. Velocity Magnitude Distribution on The Cut Line

Channel

Flow Rate

fast middle slow
5μL/min 5413.994μm/s 548.52153μm/s 67.9229μm/s
15μL/min 16241.73779μm/s 1645.63652μm/s 203.79536μm/s
45μL/min 48723.94763μm/s 4937.93255μm/s 611.65866μm/s

Table. Simulation Results of Central Line Speed of each channel

In order to obtain the exact shear force applied to the cells by the fluid flow. We inputed the experimentally used flow rate as a boundary condition( 25μL/min,50μL/min and 100μL/min) in our model, which had already been tested before. The shear stress on the bottom of every channel where the cells adhered to was also calculated.

Channel

Flow Rate

fast middle slow
25μL/min 1.07519Pa 0.10819Pa 0.0132Pa
50μL/min 2.15057Pa 0.21642Pa 0.02641Pa
100μL/min 4.30273Pa 0.43314Pa 0.05288Pa

300px
Fig. Shear Stress Distribution Under Input Flow Rate 50μL/min (log phase)

Detailed Protocol


References

  1. Booth, R., & Kim, H. (2012). Characterization of a microfluidic in vitro model of the blood-brain barrier (μBBB). Lab on a Chip, 12(10), 1784-1792.

Made by from the iGEM team SUSTech_Shenzhen.

Licensed under CC BY 4.0.