Flindeberg (Talk | contribs) |
Flindeberg (Talk | contribs) |
||
Line 19: | Line 19: | ||
<div class="col-lg-8 text"> | <div class="col-lg-8 text"> | ||
<hr> | <hr> | ||
− | + | <h3 id="intro">Introduction</h3> | |
− | We are happy to say that we now have re-introduced the Uppsala team to the interlab study after a year in absence. The flow cytometer that has been used by the Uppsala iGEM team earlier years was unavailable this year. However, we had access to a fluorescence plate reader which allowed us to participate in the interlab study using the plate reader protocol. | + | <p>We are happy to say that we now have re-introduced the Uppsala team to the interlab study after a year in absence. The flow cytometer that has been used by the Uppsala iGEM team earlier years was unavailable this year. However, we had access to a fluorescence plate reader which allowed us to participate in the interlab study using the plate reader protocol. </p> |
<h3>Method</h3> | <h3>Method</h3> | ||
Thorough instructions for the interlab study are available at <a href="https://static.igem.org/mediawiki/2016/c/c5/InterLab_iGEM2016_Plate_Reader_Protocol_Updated_July.pdf">iGEM.org</a>. The form for providing the results from the interlab study is available <a href="https://static.igem.org/mediawiki/2016/6/64/TeamName_iGEM2016_Interlab_Sheet_1_updated.xls">here</a>. | Thorough instructions for the interlab study are available at <a href="https://static.igem.org/mediawiki/2016/c/c5/InterLab_iGEM2016_Plate_Reader_Protocol_Updated_July.pdf">iGEM.org</a>. The form for providing the results from the interlab study is available <a href="https://static.igem.org/mediawiki/2016/6/64/TeamName_iGEM2016_Interlab_Sheet_1_updated.xls">here</a>. |
Revision as of 11:05, 16 October 2016
Interlab Study
Introduction
We are happy to say that we now have re-introduced the Uppsala team to the interlab study after a year in absence. The flow cytometer that has been used by the Uppsala iGEM team earlier years was unavailable this year. However, we had access to a fluorescence plate reader which allowed us to participate in the interlab study using the plate reader protocol.
Method
Thorough instructions for the interlab study are available at iGEM.org. The form for providing the results from the interlab study is available here.The protocol consists of two calibration protocols: OD600 reference point and FITC fluorescence standard curve, and a cell measurement protocol. In each protocol, there are instructions on how to perform measurements with a plate reader or a cuvette reader. Five different devices were provided by iGEM and included in the distribution kit. Positive control J23151.B0032.E0040.B0010.B0012 Negative control R0040 Device 1 J23101.B0034.E0040.B0015 Device 2 J23106.B0034.E0040.B0015 Device 3 J23117.B0034.E0040.B0015 In addition to this FITC standard and LUDOX solution was provided in the kit and used for calibration. A Shimadzu UV-1800 cuvette spectrophotometer was used for calibration and measurement of OD600. A Fluoroscan Ascent was used for the calibration and measurement of fluorescence.